ntcAupcCtrlCurModulatorPower

NEWTEC-AUPCCONTROLLER-MIB · .1.3.6.1.4.1.5835.5.2.4200.1.7.5

Object

scalar dBmInteger32
The current modulator power in dBm. Float represented as integer is scaled by
a factor of 10. i.e. a value of '-103' means '-10.3' dBm Note that the range
normally starts from
-35.0, there is one exceptional product that allows it to start from
-40.0 in a very special use case.

Context

MIB
NEWTEC-AUPCCONTROLLER-MIB
OID
.1.3.6.1.4.1.5835.5.2.4200.1.7.5
Type
scalar
Access
readonly
Status
current
Units
dBm
Parent
ntcAupcCtrlMonitoring
Groups
1

Scalars have one instance, identified by the .0 suffix.