rlSnaNextFreeSessionId
NETGEAR-RADLAN-SNA-MIB ·
.1.3.6.1.4.1.4526.17.229.1
Object
The MIB allows several SNA clients operating at the same time to receive different session ids. Get operation on this MIB will return the next free session id number. An SNA client should then issue SET operation with the value it received. The response will be one of the following: - noError. - inconsistentValue in case another client has already used this session id. - resourceUnavailable in case the number of active sessions has already reached the maximum. In case of success, a new session events database is allocated for the session id.
Context
- MIB
- NETGEAR-RADLAN-SNA-MIB
- OID
.1.3.6.1.4.1.4526.17.229.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- rlSna
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'NETGEAR-RADLAN-SNA-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'NETGEAR-RADLAN-SNA-MIB::rlSnaNextFreeSessionId.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'NETGEAR-RADLAN-SNA-MIB' -M '/opt/observium/mibs/netgear:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'NETGEAR-RADLAN-SNA-MIB::rlSnaNextFreeSessionId'
Syntax
- Source
- SNMPv2-TCTestAndIncr
- Base type
Integer32
Type Description
Represents integer-valued information used for atomic
operations. When the management protocol is used to specify
that an object instance having this syntax is to be
modified, the new value supplied via the management protocol
must precisely match the value presently held by the
instance. If not, the management protocol set operation
fails with an error of `inconsistentValue'. Otherwise, if
the current value is the maximum value of 2^31-1 (2147483647
decimal), then the value held by the instance is wrapped to
zero; otherwise, the value held by the instance is
incremented by one. (Note that regardless of whether the
management protocol set operation succeeds, the variable-
binding in the request and response PDUs are identical.)
The value of the ACCESS clause for objects having this
syntax is either `read-write' or `read-create'. When an
instance of a columnar object having this syntax is created,
any value may be supplied via the management protocol.
When the network management portion of the system is re-
initialized, the value of every object instance having this
syntax must either be incremented from its value prior to
the re-initialization, or (if the value prior to the re-
initialization is unknown) be set to a pseudo-randomly
generated value.
Values & Constraints
Type Constraints
range: 0..2147483647