nodeEnvFailedPowerSupplyMessage
NETAPP-MIB ·
.1.3.6.1.4.1.789.1.25.2.1.22
Object
column
SNMPv2-TCDisplayString
Text message describing the state of any power supplies which are currently degraded. This is useful only if envFailedPowerSupplyCount is not zero.
Context
- MIB
- NETAPP-MIB
- OID
.1.3.6.1.4.1.789.1.25.2.1.22- Type
- column
- Access
- readonly
- Status
- current
- Parent
- nodeEntry
- Table
- nodeTable
- Siblings
- 23
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| nodeName Node Name. Same as sysName for a specific node. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.789.1.25.2.1.1 |
| nodeVendor Node Vendor. Similar to productVendor for a specific node. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.789.1.25.2.1.10 |
| nodeHealth Whether or not the node can communicate with the cluster. | column | Boolean | .1.3.6.1.4.1.789.1.25.2.1.11 |
| nodeEligibility An eligible node is one that has been designated by the
administrator as an active participant in the cluster. | column | Boolean | .1.3.6.1.4.1.789.1.25.2.1.12 |
| nodeEpsilon Whether or not this node has epsilon to keep the quorum
up if only half of the nodes can communicate. | column | Boolean | .1.3.6.1.4.1.789.1.25.2.1.13 |
| nodeUuid Universally unique identifier (UUID) of the node. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.789.1.25.2.1.14 |
| nodeCpuUptime The time (in hundredths of a second) that the
CPU has been up since the last boot. | column | SNMPv2-SMITimeTicks | .1.3.6.1.4.1.789.1.25.2.1.15 |
| nodeCpuBusyTime The time (in hundredths of a second) that the
CPU has been doing useful work since the last
boot. | column | SNMPv2-SMITimeTicks | .1.3.6.1.4.1.789.1.25.2.1.16 |
| nodeNvramBatteryStatus An indication of the current status of the
NVRAM battery or batteries. Batteries which
are fully or partially discharged may not
fully protect the system during a crash.
… | column | Enumeration | .1.3.6.1.4.1.789.1.25.2.1.17 |
| nodeEnvOverTemperature An indication of whether the hardware is
currently operating outside of its recommended
temperature range. The hardware will shutdown
if the temperature exceeds critical threshol… | column | Enumeration | .1.3.6.1.4.1.789.1.25.2.1.18 |
| nodeEnvFailedFanCount Count of the number of chassis fans which
are not operating within the recommended
RPM range. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.789.1.25.2.1.19 |
| nodeOwner Node Owner. Same as sysContact for a specific node. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.789.1.25.2.1.2 |
| nodeEnvFailedFanMessage Text message describing the current condition of
chassis fans. This is useful only if
envFailedFanCount is not zero. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.789.1.25.2.1.20 |
| nodeEnvFailedPowerSupplyCount Count of the number of power supplies which
are in degraded mode. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.789.1.25.2.1.21 |
| nodeProductVersion Node Product Version. Similar to productVersion for
a specific node. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.789.1.25.2.1.23 |
| nodeFirmwareVersion Node Firmware Version. Similar to productFirmwareVersion
for a specific node. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.789.1.25.2.1.24 |
| nodeLocation Node Location. Same as sysLocation for a specific node. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.789.1.25.2.1.3 |
| nodeModel Node Model. Same as productModel for a specific node. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.789.1.25.2.1.4 |
| nodeSerialNumber Node Serial Number. Same as productSerialNum for a specific node. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.789.1.25.2.1.5 |
| nodeAssetTag Value of customer-assigned asset tag for this node. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.789.1.25.2.1.6 |
| nodeUptime Node Uptime. Same as sysUpTime for a specific node. | column | SNMPv2-SMITimeTicks | .1.3.6.1.4.1.789.1.25.2.1.7 |
| nodeNvramId NVRAM ID of this node. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.789.1.25.2.1.8 |
| nodeSystemId Node System ID. Same as productId for a specific node. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.789.1.25.2.1.9 |