nbsCmmcTrapSlotShuttingDown
NBS-CMMC-MIB ·
.1.3.6.1.4.1.629.200.13.0.37
Object
notification
Sent when the slot/card is shutting down.
This Notification should be of Severity WARNING if the
shutdown is deliberate, or ERROR if shutdown because
of module failure, i.e. last gasp.
The VARIABLE nbsCmmcTrapShutdownReason should specify
the reason the card is shutting down.
To enable/disable this notification, use the object
nbsCmmcChassisEnableModuleSpecificTraps.
Context
- MIB
- NBS-CMMC-MIB
- OID
.1.3.6.1.4.1.629.200.13.0.37- Type
- notification
- Status
- current
- Parent
- nbsCmmcTraps0
- Siblings
- 64
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| nbsCmmcTrapGenericTrap deprecated The last message sent by the system. | notification | - | .1.3.6.1.4.1.629.200.13.0.1 |
| nbsCmmcTrapChassisTempTooHigh Sent when temperature rises above hottest permissible
temperature.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.10 |
| nbsCmmcTrapChassisTempTooLow Sent when temperature falls under coldest permissible
temperature.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.11 |
| nbsCmmcTrapChassisTempOk Sent when temperature returns to permissible range.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.12 |
| nbsCmmcTrapSlotModuleIn Sent when card is physically inserted.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.13 |
| nbsCmmcTrapSlotModuleOut Sent when card is physically removed.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.14 |
| nbsCmmcTrapPortEnabled Sent after nbsCmmcPortEnableOper changes to enable(3).
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.15 |
| nbsCmmcTrapPortDisabled Sent after nbsCmmcPortEnableOper changes to disable(2).
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.16 |
| nbsCmmcTrapPortLinkUp Sent when nbsCmmcPortLink transitions from noSignal(2)
to a connected state.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.17 |
| nbsCmmcTrapPortLinkDown Sent when nbsCmmcPortLink transitions from a connected
state to noSignal(2).
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.18 |
| nbsCmmcTrapPortLINOn Sent when Link Integrity Notification is turned on.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.19 |
| nbsCmmcTrapSpecificTrap deprecated ********* DEPRECATED **********
As of Agent version 4.14, this trap will not be sent. | notification | - | .1.3.6.1.4.1.629.200.13.0.2 |
| nbsCmmcTrapPortLINOff Sent when Link Integrity Notification is turned off.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.20 |
| nbsCmmcTrapPortLoopbackOn Sent when Port is set to a Loopback state.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.21 |
| nbsCmmcTrapPortLoopbackOff Sent when Port returns from a Loopback state.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.22 |
| nbsCmmcTrapPortMaximumExceeded Sent when PortValue exceeds PortThreshold.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.23 |
| nbsCmmcTrapPortRemoved Sent when a hot-swappable port is removed.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.24 |
| nbsCmmcTrapPortInserted Sent when a hot-swappable port is inserted.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.25 |
| nbsCmmcTrapPortTempTooLow Sent when transmitter temperature is too cold. For
SFF Digital Diagnostics, this corresponds to the low
temperature alarm.
This Notification should be of Severity ERRO… | notification | - | .1.3.6.1.4.1.629.200.13.0.26 |
| nbsCmmcTrapPortTempTooHigh Sent when transmitter temperature is too hot. For
SFF Digital Diagnostics, this corresponds to the high
temperature alarm.
This Notification should be of Severity ERRO… | notification | - | .1.3.6.1.4.1.629.200.13.0.27 |
| nbsCmmcTrapPortRxPowerTooLow Sent when received signal is too weak. For
SFF Digital Diagnostics, this corresponds to the low
RX power alarm.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.28 |
| nbsCmmcTrapPortRxPowerTooHigh Sent when received signal is too powerful. For
SFF Digital Diagnostics, this corresponds to the high
RX power alarm.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.29 |
| nbsCmmcTrapDeviceRebooted Sent after device boots up. The cause of the last
shutdown is indicated in nbsCmmcTrapShutdownReason.
This Notification should be of Severity FATAL. | notification | - | .1.3.6.1.4.1.629.200.13.0.3 |
| nbsCmmcTrapPortTxPowerTooLow Sent when transmitter power is too weak. For
SFF Digital Diagnostics, this corresponds to the low
TX power alarm.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.30 |
| nbsCmmcTrapPortTxPowerTooHigh Sent when transmitter power is too strong. For
SFF Digital Diagnostics, this corresponds to the high
TX power alarm.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.31 |
| nbsCmmcTrapPortAmpsTooLow Sent when bias current is too small. For
SFF Digital Diagnostics, this corresponds to the low
bias current alarm.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.32 |
| nbsCmmcTrapPortAmpsTooHigh Sent when bias current is too large. For
SFF Digital Diagnostics, this corresponds to the high
bias current alarm.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.33 |
| nbsCmmcTrapPortVoltsTooLow Sent when transceiver supply voltage is too low. For
SFF Digital Diagnostics, this corresponds to the low
supply voltage alarm.
This Notification should be of Severity… | notification | - | .1.3.6.1.4.1.629.200.13.0.34 |
| nbsCmmcTrapPortVoltsTooHigh Sent when transceiver supply voltage is too high. For
SFF Digital Diagnostics, this corresponds to the high
supply voltage alarm.
This Notification should be of Severi… | notification | - | .1.3.6.1.4.1.629.200.13.0.35 |
| nbsCmmcTrapSwitchover Sent when a self-healing (redundant ports) card
switches traffic from an active port to a standby
port.
This Notification should be of Severity WARNING.
The … | notification | - | .1.3.6.1.4.1.629.200.13.0.36 |
| nbsCmmcTrapPortCrcError Sent when CRC Error is received on this port.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.38 |
| nbsCmmcTrapCpeInManagedChassis Sent when a module configured for customer premises is
detected in a managed (central office) chassis.
This Notification should be of Severity WARNING.
To en… | notification | - | .1.3.6.1.4.1.629.200.13.0.39 |
| nbsCmmcTrapDeviceOnline Sent when device detects restoration of network
communications. ChassisIndex and SlotIndex indicate
the location of the NM issuing the trap
This Notification should be … | notification | - | .1.3.6.1.4.1.629.200.13.0.4 |
| nbsCmmcTrapCoWithoutCpe Sent when a central office module has no link to a CPE
module.
This Notification should be of Severity WARNING.
To enable/disable this notification, use the … | notification | - | .1.3.6.1.4.1.629.200.13.0.40 |
| nbsCmmcTrapCoTakesControl Sent when a central office module begins active
management of a dual-homed CPE module.
This Notification should be of Severity WARNING.
To enable/disable thi… | notification | - | .1.3.6.1.4.1.629.200.13.0.41 |
| nbsCmmcTrapCoYieldsControl Sent when a central office module ceases active
management of a dual-homed CPE module.
This Notification should be of Severity WARNING.
To enable/disable thi… | notification | - | .1.3.6.1.4.1.629.200.13.0.42 |
| nbsCmmcTrapCoLinkedToCo Sent when one central office module is connected to
another central office module.
This Notification should be of Severity ERROR.
To enable/disable this noti… | notification | - | .1.3.6.1.4.1.629.200.13.0.43 |
| nbsCmmcTrapCpeFound Sent when a remote CPE module is detected.
This Notification should be of Severity WARNING.
To enable/disable this notification, use the object
nbsCmmcChassi… | notification | - | .1.3.6.1.4.1.629.200.13.0.44 |
| nbsCmmcTrapPortReflectionDetected Sent when SingleFiber port detects its own signal
reflecting back on itself.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.45 |
| nbsCmmcTrapPortReflectionCeased Sent when SingleFiber port no longer detects its own
signal returning.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.46 |
| nbsCmmcTrapPortTempOk Sent when transmitter temperature returns to normal.
For Agent's internal severity-based filtering.
The severity of this NOTIFICATION must match the
severity of the nbs… | notification | - | .1.3.6.1.4.1.629.200.13.0.47 |
| nbsCmmcTrapPortRxPowerOk Sent when received signal returns to normal.
For Agent's internal severity-based filtering.
The severity of this NOTIFICATION must match the
severity of the nbsCmmcTrap… | notification | - | .1.3.6.1.4.1.629.200.13.0.48 |
| nbsCmmcTrapPortTxPowerOk Sent when transmitter power returns to normal.
For Agent's internal severity-based filtering.
The severity of this NOTIFICATION must match the
severity of the nbsCmmcTr… | notification | - | .1.3.6.1.4.1.629.200.13.0.49 |
| nbsCmmcTrapDeviceShuttingDown Sent just before device shuts itself down. Reason for
shutdown is indicated in nbsCmmcTrapShutdownReason.
This Notification should be of Severity FATAL. | notification | - | .1.3.6.1.4.1.629.200.13.0.5 |
| nbsCmmcTrapPortAmpsOk Sent when bias current returns to normal.
For Agent's internal severity-based filtering.
The severity of this NOTIFICATION must match the
severity of the nbsCmmcTrapPor… | notification | - | .1.3.6.1.4.1.629.200.13.0.50 |
| nbsCmmcTrapPortVoltsOk Sent when transceiver supply voltage returns to normal.
For Agent's internal severity-based filtering.
The severity of this NOTIFICATION must match the
severity of the … | notification | - | .1.3.6.1.4.1.629.200.13.0.51 |
| nbsCmmcTrapSlotTempTooLow Sent when slot temperature is too cold.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.52 |
| nbsCmmcTrapSlotTempTooHigh Sent when slot temperature is too hot.
temperature alarm.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.53 |
| nbsCmmcTrapSlotTempOk Sent when slot temperature returns to normal.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.54 |
| nbsCmmcTrapPortErrorsDetected Sent when nbsCmmcPortErrorActivity changes to on(3).
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.55 |
| nbsCmmcTrapPortErrorsStopped Sent when nbsCmmcPortErrorActivity changes to off(2).
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.56 |
| nbsCmmcTrapChassisInsufficientPower Sent when power on chassis changed to insufficient.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.57 |
| nbsCmmcTrapChassisSufficientPower Sent when power on chassis changed to sufficient.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.58 |
| nbsCmmcTrapSlotModuleLocked Sent when nbsCmmcSysLockTypes is enabled(3) and a card
incompatible with a slot's locked configuration is
inserted.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.59 |
| nbsCmmcTrapPowerSupplyFailure Unique trap for power supply failure events.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.6 |
| nbsCmmcTrapSelectLinkChanged Sent when a redundant port in a self-healing card
switches between active and standby. The last varbind,
nbsCmmcPortSelectLink, indicates this port's new state.
This n… | notification | - | .1.3.6.1.4.1.629.200.13.0.60 |
| nbsCmmcTrapPowerSupplyRemoved Event triggered by physical removal of a power supply.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.66 |
| nbsCmmcTrapPowerSupplyInserted Triggered by physical insertion of a power supply.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.67 |
| nbsCmmcTrapFanRemoved Triggered by physical removal of fan assembly.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.68 |
| nbsCmmcTrapFanInserted Triggered by physical insertion of fan assembly.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.69 |
| nbsCmmcTrapPowerSupplyRestored Sent when power supply starts working again.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.7 |
| nbsCmmcTrapModuleStatusChanged Triggered when nbsCmmcSlotModuleStatus changes.
If a module is unplugged and nbsCmmcSlotModuleStatus
transitions directly to empty(2), a trap will not be
generated.
… | notification | - | .1.3.6.1.4.1.629.200.13.0.70 |
| nbsCmmcTrapFanFailure Unique trap for fan failure events.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.8 |
| nbsCmmcTrapFanRestored Sent when fan starts working again.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| nbsCmmcTrapLastMessage The last message sent by the system | scalar | OctetString | .1.3.6.1.4.1.629.200.12.1 |
| nbsCmmcChassisIndex The index of the Chassis. | column | Integer32 | .1.3.6.1.4.1.629.200.6.1.1.1 |
| nbsCmmcSlotIndex The slot index. | column | Integer32 | .1.3.6.1.4.1.629.200.7.1.1.2 |
| nbsCmmcTrapShutdownReason The reason for the last system shutdown | scalar | OctetString | .1.3.6.1.4.1.629.200.12.6 |
| nbsCmmcChassisName The user assigned name for this chassis | column | OctetString | .1.3.6.1.4.1.629.200.6.1.1.32 |
| nbsCmmcSlotName The user assigned name for this slot. | column | OctetString | .1.3.6.1.4.1.629.200.7.1.1.10 |