nbsCmmcTrapPortRxPowerTooLow
NBS-CMMC-MIB ·
.1.3.6.1.4.1.629.200.13.0.28
Object
notification
Sent when received signal is too weak. For
SFF Digital Diagnostics, this corresponds to the low
RX power alarm.
This Notification should be of Severity ERROR.
Context
- MIB
- NBS-CMMC-MIB
- OID
.1.3.6.1.4.1.629.200.13.0.28- Type
- notification
- Status
- current
- Parent
- nbsCmmcTraps0
- Siblings
- 64
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| nbsCmmcTrapGenericTrap deprecated The last message sent by the system. | notification | - | .1.3.6.1.4.1.629.200.13.0.1 |
| nbsCmmcTrapChassisTempTooHigh Sent when temperature rises above hottest permissible
temperature.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.10 |
| nbsCmmcTrapChassisTempTooLow Sent when temperature falls under coldest permissible
temperature.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.11 |
| nbsCmmcTrapChassisTempOk Sent when temperature returns to permissible range.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.12 |
| nbsCmmcTrapSlotModuleIn Sent when card is physically inserted.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.13 |
| nbsCmmcTrapSlotModuleOut Sent when card is physically removed.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.14 |
| nbsCmmcTrapPortEnabled Sent after nbsCmmcPortEnableOper changes to enable(3).
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.15 |
| nbsCmmcTrapPortDisabled Sent after nbsCmmcPortEnableOper changes to disable(2).
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.16 |
| nbsCmmcTrapPortLinkUp Sent when nbsCmmcPortLink transitions from noSignal(2)
to a connected state.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.17 |
| nbsCmmcTrapPortLinkDown Sent when nbsCmmcPortLink transitions from a connected
state to noSignal(2).
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.18 |
| nbsCmmcTrapPortLINOn Sent when Link Integrity Notification is turned on.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.19 |
| nbsCmmcTrapSpecificTrap deprecated ********* DEPRECATED **********
As of Agent version 4.14, this trap will not be sent. | notification | - | .1.3.6.1.4.1.629.200.13.0.2 |
| nbsCmmcTrapPortLINOff Sent when Link Integrity Notification is turned off.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.20 |
| nbsCmmcTrapPortLoopbackOn Sent when Port is set to a Loopback state.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.21 |
| nbsCmmcTrapPortLoopbackOff Sent when Port returns from a Loopback state.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.22 |
| nbsCmmcTrapPortMaximumExceeded Sent when PortValue exceeds PortThreshold.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.23 |
| nbsCmmcTrapPortRemoved Sent when a hot-swappable port is removed.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.24 |
| nbsCmmcTrapPortInserted Sent when a hot-swappable port is inserted.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.25 |
| nbsCmmcTrapPortTempTooLow Sent when transmitter temperature is too cold. For
SFF Digital Diagnostics, this corresponds to the low
temperature alarm.
This Notification should be of Severity ERRO… | notification | - | .1.3.6.1.4.1.629.200.13.0.26 |
| nbsCmmcTrapPortTempTooHigh Sent when transmitter temperature is too hot. For
SFF Digital Diagnostics, this corresponds to the high
temperature alarm.
This Notification should be of Severity ERRO… | notification | - | .1.3.6.1.4.1.629.200.13.0.27 |
| nbsCmmcTrapPortRxPowerTooHigh Sent when received signal is too powerful. For
SFF Digital Diagnostics, this corresponds to the high
RX power alarm.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.29 |
| nbsCmmcTrapDeviceRebooted Sent after device boots up. The cause of the last
shutdown is indicated in nbsCmmcTrapShutdownReason.
This Notification should be of Severity FATAL. | notification | - | .1.3.6.1.4.1.629.200.13.0.3 |
| nbsCmmcTrapPortTxPowerTooLow Sent when transmitter power is too weak. For
SFF Digital Diagnostics, this corresponds to the low
TX power alarm.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.30 |
| nbsCmmcTrapPortTxPowerTooHigh Sent when transmitter power is too strong. For
SFF Digital Diagnostics, this corresponds to the high
TX power alarm.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.31 |
| nbsCmmcTrapPortAmpsTooLow Sent when bias current is too small. For
SFF Digital Diagnostics, this corresponds to the low
bias current alarm.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.32 |
| nbsCmmcTrapPortAmpsTooHigh Sent when bias current is too large. For
SFF Digital Diagnostics, this corresponds to the high
bias current alarm.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.33 |
| nbsCmmcTrapPortVoltsTooLow Sent when transceiver supply voltage is too low. For
SFF Digital Diagnostics, this corresponds to the low
supply voltage alarm.
This Notification should be of Severity… | notification | - | .1.3.6.1.4.1.629.200.13.0.34 |
| nbsCmmcTrapPortVoltsTooHigh Sent when transceiver supply voltage is too high. For
SFF Digital Diagnostics, this corresponds to the high
supply voltage alarm.
This Notification should be of Severi… | notification | - | .1.3.6.1.4.1.629.200.13.0.35 |
| nbsCmmcTrapSwitchover Sent when a self-healing (redundant ports) card
switches traffic from an active port to a standby
port.
This Notification should be of Severity WARNING.
The … | notification | - | .1.3.6.1.4.1.629.200.13.0.36 |
| nbsCmmcTrapSlotShuttingDown Sent when the slot/card is shutting down.
This Notification should be of Severity WARNING if the
shutdown is deliberate, or ERROR if shutdown because
of module failure,… | notification | - | .1.3.6.1.4.1.629.200.13.0.37 |
| nbsCmmcTrapPortCrcError Sent when CRC Error is received on this port.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.38 |
| nbsCmmcTrapCpeInManagedChassis Sent when a module configured for customer premises is
detected in a managed (central office) chassis.
This Notification should be of Severity WARNING.
To en… | notification | - | .1.3.6.1.4.1.629.200.13.0.39 |
| nbsCmmcTrapDeviceOnline Sent when device detects restoration of network
communications. ChassisIndex and SlotIndex indicate
the location of the NM issuing the trap
This Notification should be … | notification | - | .1.3.6.1.4.1.629.200.13.0.4 |
| nbsCmmcTrapCoWithoutCpe Sent when a central office module has no link to a CPE
module.
This Notification should be of Severity WARNING.
To enable/disable this notification, use the … | notification | - | .1.3.6.1.4.1.629.200.13.0.40 |
| nbsCmmcTrapCoTakesControl Sent when a central office module begins active
management of a dual-homed CPE module.
This Notification should be of Severity WARNING.
To enable/disable thi… | notification | - | .1.3.6.1.4.1.629.200.13.0.41 |
| nbsCmmcTrapCoYieldsControl Sent when a central office module ceases active
management of a dual-homed CPE module.
This Notification should be of Severity WARNING.
To enable/disable thi… | notification | - | .1.3.6.1.4.1.629.200.13.0.42 |
| nbsCmmcTrapCoLinkedToCo Sent when one central office module is connected to
another central office module.
This Notification should be of Severity ERROR.
To enable/disable this noti… | notification | - | .1.3.6.1.4.1.629.200.13.0.43 |
| nbsCmmcTrapCpeFound Sent when a remote CPE module is detected.
This Notification should be of Severity WARNING.
To enable/disable this notification, use the object
nbsCmmcChassi… | notification | - | .1.3.6.1.4.1.629.200.13.0.44 |
| nbsCmmcTrapPortReflectionDetected Sent when SingleFiber port detects its own signal
reflecting back on itself.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.45 |
| nbsCmmcTrapPortReflectionCeased Sent when SingleFiber port no longer detects its own
signal returning.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.46 |
| nbsCmmcTrapPortTempOk Sent when transmitter temperature returns to normal.
For Agent's internal severity-based filtering.
The severity of this NOTIFICATION must match the
severity of the nbs… | notification | - | .1.3.6.1.4.1.629.200.13.0.47 |
| nbsCmmcTrapPortRxPowerOk Sent when received signal returns to normal.
For Agent's internal severity-based filtering.
The severity of this NOTIFICATION must match the
severity of the nbsCmmcTrap… | notification | - | .1.3.6.1.4.1.629.200.13.0.48 |
| nbsCmmcTrapPortTxPowerOk Sent when transmitter power returns to normal.
For Agent's internal severity-based filtering.
The severity of this NOTIFICATION must match the
severity of the nbsCmmcTr… | notification | - | .1.3.6.1.4.1.629.200.13.0.49 |
| nbsCmmcTrapDeviceShuttingDown Sent just before device shuts itself down. Reason for
shutdown is indicated in nbsCmmcTrapShutdownReason.
This Notification should be of Severity FATAL. | notification | - | .1.3.6.1.4.1.629.200.13.0.5 |
| nbsCmmcTrapPortAmpsOk Sent when bias current returns to normal.
For Agent's internal severity-based filtering.
The severity of this NOTIFICATION must match the
severity of the nbsCmmcTrapPor… | notification | - | .1.3.6.1.4.1.629.200.13.0.50 |
| nbsCmmcTrapPortVoltsOk Sent when transceiver supply voltage returns to normal.
For Agent's internal severity-based filtering.
The severity of this NOTIFICATION must match the
severity of the … | notification | - | .1.3.6.1.4.1.629.200.13.0.51 |
| nbsCmmcTrapSlotTempTooLow Sent when slot temperature is too cold.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.52 |
| nbsCmmcTrapSlotTempTooHigh Sent when slot temperature is too hot.
temperature alarm.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.53 |
| nbsCmmcTrapSlotTempOk Sent when slot temperature returns to normal.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.54 |
| nbsCmmcTrapPortErrorsDetected Sent when nbsCmmcPortErrorActivity changes to on(3).
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.55 |
| nbsCmmcTrapPortErrorsStopped Sent when nbsCmmcPortErrorActivity changes to off(2).
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.56 |
| nbsCmmcTrapChassisInsufficientPower Sent when power on chassis changed to insufficient.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.57 |
| nbsCmmcTrapChassisSufficientPower Sent when power on chassis changed to sufficient.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.58 |
| nbsCmmcTrapSlotModuleLocked Sent when nbsCmmcSysLockTypes is enabled(3) and a card
incompatible with a slot's locked configuration is
inserted.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.59 |
| nbsCmmcTrapPowerSupplyFailure Unique trap for power supply failure events.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.6 |
| nbsCmmcTrapSelectLinkChanged Sent when a redundant port in a self-healing card
switches between active and standby. The last varbind,
nbsCmmcPortSelectLink, indicates this port's new state.
This n… | notification | - | .1.3.6.1.4.1.629.200.13.0.60 |
| nbsCmmcTrapPowerSupplyRemoved Event triggered by physical removal of a power supply.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.66 |
| nbsCmmcTrapPowerSupplyInserted Triggered by physical insertion of a power supply.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.67 |
| nbsCmmcTrapFanRemoved Triggered by physical removal of fan assembly.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.68 |
| nbsCmmcTrapFanInserted Triggered by physical insertion of fan assembly.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.69 |
| nbsCmmcTrapPowerSupplyRestored Sent when power supply starts working again.
This Notification should be of Severity ERROR. | notification | - | .1.3.6.1.4.1.629.200.13.0.7 |
| nbsCmmcTrapModuleStatusChanged Triggered when nbsCmmcSlotModuleStatus changes.
If a module is unplugged and nbsCmmcSlotModuleStatus
transitions directly to empty(2), a trap will not be
generated.
… | notification | - | .1.3.6.1.4.1.629.200.13.0.70 |
| nbsCmmcTrapFanFailure Unique trap for fan failure events.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.8 |
| nbsCmmcTrapFanRestored Sent when fan starts working again.
This Notification should be of Severity WARNING. | notification | - | .1.3.6.1.4.1.629.200.13.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| nbsCmmcTrapLastMessage The last message sent by the system | scalar | OctetString | .1.3.6.1.4.1.629.200.12.1 |
| nbsCmmcChassisIndex The index of the Chassis. | column | Integer32 | .1.3.6.1.4.1.629.200.6.1.1.1 |
| nbsCmmcSlotIndex The slot index. | column | Integer32 | .1.3.6.1.4.1.629.200.7.1.1.2 |
| nbsCmmcPortIndex The index of the Port in the Slot in the Chassis to
which this port is connected. | column | Integer32 | .1.3.6.1.4.1.629.200.8.1.1.3 |
| nbsCmmcPortRxPower The received optical power (in milli dBm) of this
receiver.
Not supported value: 0x80000000 | column | Integer32 | .1.3.6.1.4.1.629.200.8.1.1.32 |
| nbsCmmcChassisName The user assigned name for this chassis | column | OctetString | .1.3.6.1.4.1.629.200.6.1.1.32 |
| nbsCmmcSlotName The user assigned name for this slot. | column | OctetString | .1.3.6.1.4.1.629.200.7.1.1.10 |
| nbsCmmcPortName The user assigned name for this port. This object is also
used for the MIB2 object ifAlias. | column | OctetString | .1.3.6.1.4.1.629.200.8.1.1.21 |
| nbsCmmcPortThreshold Port Threshold - usage may be different for each card.
For card 197, this indicates the minimum signal
strength. Value ranges from -5 to -40 decibels.
For card 211, valid valu… | column | Integer32 | .1.3.6.1.4.1.629.200.8.1.1.23 |
| nbsCmmcPortRxPowerLevel This object indicates whether this port has a problem
with the power of its received signal.
If this port does not support SFF-8472 Digital Diagnostics,
this value … | column | Enumeration | .1.3.6.1.4.1.629.200.8.1.1.66 |