mdmCCCallSetUpFailTimer
Modem-MIB ·
.1.3.6.1.2.1.38.1.1.7.1.2
Object
column
r/w
Integer32
This parameter specifies the amount of time, in seconds,
that the modem shall allow between either answering a call
(automatically or manually) or completion of dialing, and
establishment of a connection with the remote modem. If no
connection is established during this time, the modem
disconnects from the line and returns a result code
indicating the cause of the disconnection. In TIA-602, this
is controlled by the value in the S7 register.
Context
- MIB
- Modem-MIB
- OID
.1.3.6.1.2.1.38.1.1.7.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- mdmCallControlEntry
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-255