mwrThroughputThresholdParams

MWR-ETHERNET-MIB · .1.3.6.1.4.1.7262.4.5.9.1.2.1.1.4

Object

This object configures the radio throughput threshold settings. The threshold, in percent and the number of seconds that it must exceed this threshold. An example of the format of the string is as follows: '70 10'. The first parameter is the percentage of the throughput, the second is the time in seconds that the threshold must be exceeded. The single quote marks i.e. ' ' are not used in the command

Context

MIB
MWR-ETHERNET-MIB
OID
.1.3.6.1.4.1.7262.4.5.9.1.2.1.1.4
Type
column
Access
readwrite
Status
current
Parent
mwrPortThresholdAlarmEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'MWR-ETHERNET-MIB' -M '/opt/observium/mibs/dragonwave:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MWR-ETHERNET-MIB::mwrThroughputThresholdParams'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'MWR-ETHERNET-MIB' -M '/opt/observium/mibs/dragonwave:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'MWR-ETHERNET-MIB::mwrThroughputThresholdParams.<mwrPortThresholdAlarmIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'MWR-ETHERNET-MIB' -M '/opt/observium/mibs/dragonwave:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'MWR-ETHERNET-MIB::mwrThroughputThresholdParams'

Syntax

Source
SNMPv2-TCDisplayString
Base type
OctetString
Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
          
character set, as defined in pages 4, 10-11 of RFC 854.
          
To summarize RFC 854, the NVT ASCII repertoire specifies:
          
  - the use of character codes 0-127 (decimal)
          
  - the graphics characters (32-126) are interpreted as
    US ASCII
          
  - NUL, LF, CR, BEL, BS, HT, VT and FF have the special
    meanings specified in RFC 854
          
  - the other 25 codes have no standard interpretation
          
  - the sequence 'CR LF' means newline
          
  - the sequence 'CR NUL' means carriage-return
          
  - an 'LF' not preceded by a 'CR' means moving to the
    same column on the next line.
          
  - the sequence 'CR x' for any x other than LF or NUL is
    illegal.  (Note that this also means that a string may
    end with either 'CR LF' or 'CR NUL', but not with CR.)
          
Any object defined using this syntax may not exceed 255
characters in length.

Values & Constraints

Type Constraints
range: 0..255