mefSoamLmCfgEnabled

MEF-SOAM-PM-MIB · .1.3.6.1.4.1.15007.1.3.1.2.1.1.4

Object

column r/w SNMPv2-TCTruthValue
This object specifies whether the Loss Measurement session
is enabled. 
              
The value 'true' indicates the Loss Measurement session is enabled and
SOAM PDUs are sent and/or measurements are collected when the session
is running according to the scheduling objects (start time, stop time,
etc.).
              
The value 'false' indicates the Loss Measurement session is disabled
and SOAM PDUs are not sent and/or measurements collected.
              
For a Loss Measurement session to be removed the row is 
deleted in order to release internal resources.
              
This object can written/modified after row creation time.
              
If the LM session is enabled it resumes after shutdown/restart.
              
If the LM session is disabled the current Measurement Interval is 
stopped, if it in process at the time, and all the in process calculations
for the partially completed Measurement Interval are finalized.
              
This object does not affect whether the single-ended Responder is
enabled or not, which is enabled or disabled by the 
mefSoamPmMepLmSingleEndedResponder and 
mefSoamPmMepSlmSingleEndedResponder objects.