mefSoamLmCfgAvailabilityNumConsecutiveMeasPdus
MEF-SOAM-PM-MIB ·
.1.3.6.1.4.1.15007.1.3.1.2.1.1.27
Object
column
r/w
Unsigned32
This object specifies a configurable number of consecutive
loss measurement PDUs to be used in evaluating the
availability/unavailability status of each availability
indicator per MEF 10.2.1. Loss Measurement PDUs (LMMs, CCMs or
SLMs) are sent regularly with a period defined by
mefSoamLmCfgMessagePeriod. Therefore, this object, when
multiplied by mefSoamLmCfgMessagePeriod, is equivalent to
the Availability parameter of 'delta_t' as specified by MEF 10.2.1.
If the mefSoamLmCfgType is lmLMM or lmCCM, this object defines the
number of LMM or CCM PDUs transmitted during each 'delta_t' period.
The Availability flr for a given 'delta_t' can be calculated based
on the counters in the last LMM/R or CCM during this 'delta_t' and
the last LMM/R or CCM in the previous 'delta_t'.
If the mefSoamLmCfgType is lmSLM, this object defines the number
of SLM PDUs transmitted during each 'delta_t' period. The
Availability flr for a given 'delta_t' is calculated based on the
number of those SLM PDUs that are lost.
If the mefSoamLmCfgType is lmLMM or lmCCM, the number range of 1
through 10 must be supported. The number range of 10 through 1000000
may be supported, but is not mandatory.
If the mefSoamLmCfgType is lmSLM, the number range of 10 through
100 must be supported. The number range of 100 through 1000000
may be supported, but is not mandatory.
This object can only be written at row creation time and cannot be
modified once it has been created.
Context
- MIB
- MEF-SOAM-PM-MIB
- OID
.1.3.6.1.4.1.15007.1.3.1.2.1.1.27- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- mefSoamLmCfgEntry
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-1000000