mefSoamDmCfgMeasBinLowerBound

MEF-SOAM-PM-MIB · .1.3.6.1.4.1.15007.1.3.1.3.2.1.3

Object

column r/w microseconds (us) Unsigned32
This object specifies the lower boundary for a 
measurement bin. The upper boundary is defined by the next bin
value or infinite for the last bin defined.
The measurement boundary for each measurement bin is to  
be larger than the measurement boundary of the preceding 
measurement bin. By default, the next bin is set to 5000us larger 
than the lower bin boundary. 
              
The values in a bin boundary object represents the time range 
used to segregate delay data into the appropriate statistical
data bin. For five bins with default values, each bin has the 
following time range:
              
bin 1 =     0, range is 0us <= measurement < 5,000us
bin 2 =  5000, range is 5,000us <= measurement < 10,000us
bin 3 = 10000, range is 10,000us <= measurement < 15,000us
bin 4 = 15000, range is 15,000us <= measurement < 20,000us
bin 5 = 20000, range is 20,000us <= measurement < infinity
              
The first bin boundary (mefSoamDmCfgBinNumber set to 1) always contains 
the value of 0. Attempting to write a non-zero value to this bin will 
result in an error.

Context

MIB
MEF-SOAM-PM-MIB
OID
.1.3.6.1.4.1.15007.1.3.1.3.2.1.3
Type
column
Access
readwrite
Status
current
Units
microseconds (us)
Parent
mefSoamDmCfgMeasBinEntry

Syntax

microseconds (us) Unsigned32

Values & Constraints