softwareCuRepSwPackagesMissing
LUM-SOFTWARE-MIB ·
.1.3.6.1.4.1.8708.2.28.2.8.6
Object
scalar
LUM-TCFaultStatus
Software package file(s) are missing on master CU.
When replacing or introducing CU or TU units some software
packages needs to be downloaded to the master CU in order to
automatically upgrade the software running on the replacement
unit.
Please perform an upgrade (or download) to current
enm-release spec file (without rebooting). The alarm should
then be cleared within 5 minutes.
Note that when this alarm is cleared, the alarm 'SW not
distributed' might be seen in up to approximately 5 minutes
before the system has assured that CU SW packages are
transferred to TU units.
Context
- MIB
- LUM-SOFTWARE-MIB
- OID
.1.3.6.1.4.1.8708.2.28.2.8.6- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- softwareCuRep
Syntax
LUM-TCFaultStatus
Values & Constraints