roadmGroupLineAdminStatus

LUM-ROADM-MIB · .1.3.6.1.4.1.8708.2.31.2.5.1.1.7

Object

The administrative state for the interface.
              
down - The interface should be inactive. The ROADM add-drop
interface and the line interface are working independently.
              
service - The interface is activated but alarms are suppressed.
Intended for use during service or re-configuration. When
service is concluded adminStatus should be set to 'up' again.
              
up - The interface should be activate. Alarms are not suppressed.
All line interface belonging to this ROADM-line group are only
allowed to transmit traffic if the channel matches the drop band
of the add-drop interface.
If ROADM add-drop interface is in express mode, the line interface
are not allowed to transmit traffic.

Context

MIB
LUM-ROADM-MIB
OID
.1.3.6.1.4.1.8708.2.31.2.5.1.1.7
Type
column
Access
readonly
Status
deprecated
Default
up
Parent
roadmGroupLineEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LUM-ROADM-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-ROADM-MIB::roadmGroupLineAdminStatus'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'LUM-ROADM-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-ROADM-MIB::roadmGroupLineAdminStatus.<roadmGroupLineIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'LUM-ROADM-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'LUM-ROADM-MIB::roadmGroupLineAdminStatus'

Syntax

Source
LUM-TCBoardOrInterfaceAdminStatus
Base type
Enumeration
Type Description
The administrative state for a board or
interface.
          
down - The board/interface should be inactive.
          
service - The board/interface is activated but
alarms are suppressed. Intended for use during
service or re-configuration. When service is
concluded adminStatus should be set to 'up'
again.
          
up - The board/interface should be activated when
it becomes available. Alarms are not suppressed.

Values & Constraints

Type Values
1down
2service
3up

Conformance