ocmIfMaxPowerOffsetAdjustmentReached
LUM-OCM-MIB ·
.1.3.6.1.4.1.8708.2.33.2.2.1.1.43
Object
column LUM-TCFaultStatus
The OCM module performs a periodic power offset adjustment to fine tune
the differences between actual power measured at the OCM and total
amplifier output power deducted with the power offset value. An alarm
raised when the power difference is found to be above the threshold.
A: The calibration factor has reached its maximum of +-1.5 dB.
An alarm indicates unexpected high losses of the patch cord connecting
the OCM or a faulty set power offset. Power offset is normally read
from the connected amplifier.
D: When calibration factor is less than +-1.5 dB.
Context
- MIB
- LUM-OCM-MIB
- OID
.1.3.6.1.4.1.8708.2.33.2.2.1.1.43- Type
- column
- Access
- readonly
- Status
- current
- Parent
- ocmIfEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LUM-OCM-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-OCM-MIB::ocmIfMaxPowerOffsetAdjustmentReached'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'LUM-OCM-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-OCM-MIB::ocmIfMaxPowerOffsetAdjustmentReached.<ocmIfIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'LUM-OCM-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'LUM-OCM-MIB::ocmIfMaxPowerOffsetAdjustmentReached'
Syntax
- Source
- LUM-TCFaultStatus
- Base type
Enumeration
Type Description
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.
ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
alarm - indicates that a fault condition is present
and an alarm is active.
Note: The list of FaultStatus objects forms the list of all
potential alarms for the system.
Values & Constraints
Type Values
1 | ok |
2 | alarm |
Conformance
Member of