oaIfRegulationProblemTxPowerHigh

LUM-OA-MIB · .1.3.6.1.4.1.8708.2.19.2.2.1.1.29

Object

The output power is above meassuring range.
              
A: The received power level exceeds the
associated threshold.
              
D: The received power level is 0.5 dBm below
the threshold.

Context

MIB
LUM-OA-MIB
OID
.1.3.6.1.4.1.8708.2.19.2.2.1.1.29
Type
column
Access
readonly
Status
current
Parent
oaIfEntry
Groups
15

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LUM-OA-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-OA-MIB::oaIfRegulationProblemTxPowerHigh'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'LUM-OA-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-OA-MIB::oaIfRegulationProblemTxPowerHigh.<oaIfIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'LUM-OA-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'LUM-OA-MIB::oaIfRegulationProblemTxPowerHigh'

Syntax

Source
LUM-TCFaultStatus
Base type
Enumeration
Type Description
A value indicating the current state
of a potential fault condition leading to
an alarm for an object.
          
ok - indicates that no fault condition is present
and no alarm is active or the alarm has been cleared.
          
alarm - indicates that a fault condition is present
and an alarm is active.
          
Note: The list of FaultStatus objects forms the list of all
potential alarms for the system.

Values & Constraints

Type Values
1ok
2alarm