dcnOtdrLatestMeasurement
LUM-DCN-MIB ·
.1.3.6.1.4.1.8708.2.20.2.8.1.1.9
Object
column SNMPv2-TCDisplayString
Latest measurement.
Fiber reflections presented in a comma separated list,
for example Latest measurements = '102, 429, 1532 (m)'.
The values show the distance from the site to the fiber reflections.
The fiber reflections could correspond to e.g. fiber patches,
splices or the fiber end.
The last reflection may correspond to the end of the fiber.
If it is shorter than expected, this could indicate a broken fiber
and the approximate distance to the fiber break.
Context
- MIB
- LUM-DCN-MIB
- OID
.1.3.6.1.4.1.8708.2.20.2.8.1.1.9- Type
- column
- Access
- readonly
- Status
- current
- Default
""- Parent
- dcnOtdrEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LUM-DCN-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-DCN-MIB::dcnOtdrLatestMeasurement'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'LUM-DCN-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-DCN-MIB::dcnOtdrLatestMeasurement.<dcnOtdrIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'LUM-DCN-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'LUM-DCN-MIB::dcnOtdrLatestMeasurement'
Syntax
- Source
- SNMPv2-TCDisplayString
- Base type
OctetString- Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as
US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special
meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the
same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is
illegal. (Note that this also means that a string may
end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255
characters in length.
Values & Constraints
Type Constraints
range: 0..255
Conformance
Member of