alarmGeneralSoakInInterval
LUM-ALARM-MIB ·
.1.3.6.1.4.1.8708.2.1.2.1.23
Object
scalar
r/w
Unsigned32
The interval (in minutes) with which the interfaces in the node change state from Auto In-Service to In-Service after it expires. To disable the Soak-in interval set it to 0. Acceptable value is in the range 5m to 24h (1440m).
Context
- MIB
- LUM-ALARM-MIB
- OID
.1.3.6.1.4.1.8708.2.1.2.1.23- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- alarmGeneral
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-1440