alarmGeneralSoakInInterval

LUM-ALARM-MIB · .1.3.6.1.4.1.8708.2.1.2.1.23

Object

scalar r/w Unsigned32
The interval (in minutes) with
which the interfaces in the node change
state from Auto In-Service to
In-Service after it expires.
To disable the Soak-in interval
set it to 0. Acceptable value is
in the range 5m to 24h (1440m).

Context

MIB
LUM-ALARM-MIB
OID
.1.3.6.1.4.1.8708.2.1.2.1.23
Type
scalar
Access
readwrite
Status
current
Default
0
Parent
alarmGeneral
Groups
2

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'LUM-ALARM-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LUM-ALARM-MIB::alarmGeneralSoakInInterval.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'LUM-ALARM-MIB' -M '/opt/observium/mibs/infinera:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'LUM-ALARM-MIB::alarmGeneralSoakInInterval'

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 0-1440