bbuFRU
LSI-MegaRAID-SAS-MIB ·
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.26
Object
bbu FRU
Context
- MIB
- LSI-MegaRAID-SAS-MIB
- OID
.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.26- Type
- column
- Access
- readonly
- Status
- optional
- Parent
- bbuEntry
- Table
- bbuTable
- Siblings
- 33
Syntax
RFC1213-MIBDisplayString
- Source
- RFC1213-MIBDisplayString
- Base type
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| bbuID optional BBUID for this BBU.(Unique) | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.1 |
| autoLearnPeriod optional Time (in seconds) between learn cycles (0 to disable auto learn) | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.10 |
| relStateOfCharge optional Predicted remaining capacity expressed as % of FullChargeCapacity() (0-100). Value of -1 means not supported | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.11 |
| capacityRemain optional Predicted charge or energy remaining in the battery in joules | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.12 |
| runTimeToEmpty optional Relative gain or loss in remaining life in response to change in power policy represent in minute. Value of -1 means not supported | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.13 |
| avgTimeToFull optional One-minute rolling average of predicted remaining time to full charge. Value of -1 means not supported | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.14 |
| errorMargin optional Expected margin of error (%) in charge calculation (2-100). Value of -1 means not supported | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.15 |
| temperature optional Battery temperature in degree Centigrade | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.16 |
| mfgName optional Battery manufacturer's name | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.17 |
| deviceName optional Battery name | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.18 |
| serialNumber optional Battery serialNumber | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.19 |
| batteryType optional BBU Type. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.2 |
| chargerStatus optional Battery charger status. Values: N/A(-1), off(0), complete(1), progress(2) | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.20 |
| adpID optional The adapter id where BBU is attached | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.21 |
| remainingCapAlarm optional Remaining capacity to alarm. Value of -1 means not supported | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.22 |
| remainingTimeAlarm optional Remaining time to alarm. Value of -1 means not supported | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.23 |
| bbu-current optional Current(In mA) being supplied (or accepted) through the battery terminals | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.24 |
| gasGaugeStatus optional Gas gauge status | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.25 |
| batteryReplacement optional This property denotes whether the Battery needs to be replaced or not.1 =battery needs to be replaced ,0 =battery needs not to be replaced | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.27 |
| bbuRetentiontime optional The total no. of hours the battery can support the current capacity reserve. Undefined(0),48 hours+(>48),the exact no of hours(<=48) | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.28 |
| bbuState optional This property gives the Information about BBU state. Operational = if BBU is working fine, Non-Operational = if BBU is not working fine | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.29 |
| nextLearnTime optional Time of next scheduled learn cycle (seconds past 1/1/2000) | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.3 |
| memoryModuleFRU optional tmm FRU | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.30 |
| bbumoduleVersion optional Battery Firmware Version | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.31 |
| autoLearnMode optional Automatic Learn Mode | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.32 |
| chargingStatus optional Charging Status | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.33 |
| capacitance optional Capacitance | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.34 |
| absStateOfCharge optional Predicted remaining capacity expressed as % of DesignCapacity() (0-100). Value of -1 means not supported | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.4 |
| fullChargeCapacity optional Predicted pack capacity when it is fully charged in joules | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.5 |
| averageEmptyTime optional One-minute rolling average of the predicted remaining battery life. Value of -1 means not supported | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.6 |
| cycleCount optional Number of charge cycles the battery has experienced. Value of -1 means not supported | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.7 |
| firmwareStatus optional Condition of battery in following order:
packMissing(0/1)
voltageLow(0/1)
temperatureHigh(0/1)
chargeActive(0/1)
dischargeActive(0/1) … | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.8 |
| voltage optional Accurate battery terminal voltage in mV, resolution of 1mV | column | Integer32 | .1.3.6.1.4.1.3582.4.1.4.1.6.2.1.9 |