lmpLinkVerifyWavelength

LMP-MIB · .1.3.6.1.2.1.10.227.1.14.1.6

Object

column r/w nanometersSNMPv2-SMIUnsigned32
This value corresponds to the wavelength at
which the Test messages will be transmitted and is
measured in nanometers (nm).  If each data-bearing link
corresponds to a separate wavelength, then this value should
be set to 0.

Context

MIB
LMP-MIB
OID
.1.3.6.1.2.1.10.227.1.14.1.6
Type
column
Access
readwrite
Status
current
Units
nanometers
Parent
lmpLinkVerificationEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LMP-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LMP-MIB::lmpLinkVerifyWavelength'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'LMP-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LMP-MIB::lmpLinkVerifyWavelength.<ifIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'LMP-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'LMP-MIB::lmpLinkVerifyWavelength'

Syntax

Source
SNMPv2-SMIUnsigned32
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Conformance

Member of
Compliance refinements
Write access is not required.