lldpV2TxCreditMax
LLDP-V2-MIB ·
.1.3.111.2.802.1.1.13.1.1.5
Object
scalar
r/w
PDUs Unsigned32
The maximum number of consecutive LLDPDUs that can be
transmitted at any time.
The default value for lldpV2TxCreditMax object is 5 PDUs.
The value of this object is used as the initial value of
the lldpV2PortTxCreditMax object on row creation in
the lldpV2PortConfigTableV2.
The value of this object is restored from non-volatile
storage after a re-initialization of the management system.
Context
- MIB
- LLDP-V2-MIB
- OID
.1.3.111.2.802.1.1.13.1.1.5- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- PDUs
- Parent
- lldpV2Configuration
Syntax
PDUs Unsigned32
Values & Constraints
Object Constraints
range: 1-100