lgpConditionOutputToLoadOverCurrent
LIEBERT-GP-CONDITIONS-MIB ·
.1.3.6.1.4.1.476.1.42.3.2.1.53.3
Object
node
The system has detected the output to load is in an over-current condition. The current for the load has risen above a pre-determined threshold for a device, or system, defined amount of time.
Context
- MIB
- LIEBERT-GP-CONDITIONS-MIB
- OID
.1.3.6.1.4.1.476.1.42.3.2.1.53.3- Type
- node
- Status
- current
- Parent
- lgpConditionOverCurrent
- Siblings
- 11
- Children
- 3
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| lgpConditionSource1OverCurrent The system has detected an over current condition on source 1.
The current of a source has risen above a pre-determined
threshold for a device, or system, defined amount of time. | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.1 |
| lgpConditionInputOverCurrent There is an over current condition on the system input power.
The input current has risen above a pre-determined threshold for
a pre-defined amount of time. | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.10 |
| lgpConditionSource1NeutralOverCurrent The system has detected an over current condition on the neutral
line of source 1. The neutral current at source 1 has risen above
a pre-determined threshold for a pre-defined amo… | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.11 |
| lgpConditionSource2NeutralOverCurrent The system has detected an over current condition on the neutral
line of source 2. The neutral current at source 2 has risen above
a pre-determined threshold for a pre-defined amo… | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.12 |
| lgpConditionSource2OverCurrent The system has detected an over current condition on source 2.
The current of a source has risen above a pre-determined
threshold for a device, or system, defined amount of time. | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.2 |
| lgpConditionGroundOverCurrent A ground source is experiencing an over-current condition. The
current for the ground line has risen above a pre-determined
threshold for a device, or system, defined amount of t… | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.4 |
| lgpConditionRectifierOverCurrent The system has detected a rectifier over current condition.
The current for the rectifier has risen above a pre-determined
threshold for a device, or system, defined amount of tim… | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.5 |
| lgpConditionInverterOverCurrent The system has detected an inverter over current condition.
The current for the inverter has risen above a pre-determined
threshold for a device, or system, defined amount of time. | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.6 |
| lgpConditionBatteryConverterOverCurrent The system has detected an over current condition on the battery
converter. The current of the converter has risen above a
pre-determined threshold for a device, or system, defin… | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.7 |
| lgpConditionBatteryBalancerOverCurrent The system has detected a battery balancer over current condition.
The current at this point has risen above a pre-determined
threshold for a device, or system, defined amount of … | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.8 |
| lgpConditionHumidifierOverCurrent The system has detected an over current condition on the
humidifier. The current of the humidifier has risen above
a pre-determined threshold for a defined amount of time. | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| lgpConditionOutputToLoadOverCurrentPhsA The system has detected the output to load on phase A is in an
over-current condition. The current on this phase has risen above
a pre-determined threshold for a device, or syste… | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.3.1 |
| lgpConditionOutputToLoadOverCurrentPhsB The system has detected the output to load on phase B is in an
over-current condition. The current on this phase has risen above
a pre-determined threshold for a device, or syste… | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.3.2 |
| lgpConditionOutputToLoadOverCurrentPhsC The system has detected the output to load on phase C is in an
over-current condition. The current on this phase has risen above
a pre-determined threshold for a device, or syste… | node | - | .1.3.6.1.4.1.476.1.42.3.2.1.53.3.3 |