vnicNewCfgGroupAddKey
LENOVO-GbTOR-G8264-MIB ·
.1.3.6.1.4.1.26543.2.7.6.16.10.1.11
Object
Add a uplink LACP trunk to the vNIC group.
Context
- MIB
- LENOVO-GbTOR-G8264-MIB
- OID
.1.3.6.1.4.1.26543.2.7.6.16.10.1.11- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- vnicNewCfgGroupEntry
- Table
- vnicNewCfgGroupTable
- Siblings
- 16
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| vnicNewCfgGroupIndex The vNIC group number. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.26543.2.7.6.16.10.1.1 |
| vnicNewCfgGroupRemTrunk Remove the uplink trunk from the vNIC group.
other(1) is returned always when read.
The following values are writable: delete(2)...to delete the uplink trunk from the vNIC group | column | Enumeration | .1.3.6.1.4.1.26543.2.7.6.16.10.1.10 |
| vnicNewCfgGroupRemKey Remove the uplink LACP trunk from the vNIC group.
other(1) is returned always when read.
The following values are writable: delete(2)...to delete the uplink LACP trunk from the vN… | column | Enumeration | .1.3.6.1.4.1.26543.2.7.6.16.10.1.12 |
| vnicNewCfgGroupDelete Delete the vNIC group.
other(1) is returned always when read.
The following values are writable: delete(2)...to delete the vNIC group | column | Enumeration | .1.3.6.1.4.1.26543.2.7.6.16.10.1.13 |
| vnicNewCfgGroupVnics The vNICs in the vNIC group. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.26543.2.7.6.16.10.1.14 |
| vnicNewCfgGroupPorts Non-vNIC Ports and/or uplink port in the vNIC group. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.26543.2.7.6.16.10.1.15 |
| vnicNewCfgGroupTrunk Uplink trunk in the vNIC group. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.26543.2.7.6.16.10.1.16 |
| vnicNewCfgGroupKey Uplink LACP admin key in the vNIC group. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.26543.2.7.6.16.10.1.17 |
| vnicNewCfgGroupState Enable/disalbe the vNIC group. | column | Enumeration | .1.3.6.1.4.1.26543.2.7.6.16.10.1.2 |
| vnicNewCfgGroupVlan Set the vNIC group vlan number. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.26543.2.7.6.16.10.1.3 |
| vnicNewCfgGroupFailoverState Set the vNIC group failover state. | column | Enumeration | .1.3.6.1.4.1.26543.2.7.6.16.10.1.4 |
| vnicNewCfgGroupAddVnic Add a vNIC to the vNIC group. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.26543.2.7.6.16.10.1.5 |
| vnicNewCfgGroupRemVnic Remove a vNIC to the vNIC group. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.26543.2.7.6.16.10.1.6 |
| vnicNewCfgGroupAddPort Add a non-vNIC port or a uplink port to the vNIC group. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.26543.2.7.6.16.10.1.7 |
| vnicNewCfgGroupRemPort Remove a non-vNIC port or a uplink port from the vNIC group. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.26543.2.7.6.16.10.1.8 |
| vnicNewCfgGroupAddTrunk Add a uplink trunk to the vNIC group. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.26543.2.7.6.16.10.1.9 |