hwGlobalHealthStatus

LENOVO-GbTOR-G8264-MIB · .1.3.6.1.4.1.26543.2.7.6.1.3.1.15

Object

scalar Enumeration
This variable summarizes the statuses of several key elements of the device.
OK:
   - All temperature sensors are below the warning threshold (eg. < 85 C);
   - All fans are running at >= 100 RPMs;
   - Both power supplies are on;
   - No panic dump exists in flash.
Non-critical:
   - One or more temperature sensors is in the warning range (eg. >= 85 and < 100 C);
   - A panic dump exists in flash.
Critical:
   - One or more temperature sensors is in the failure range (eg. >= 100 C);
   - One or more fans are running < 100 RPM;
   - One power supply is off.
It is deprecated.

Context

MIB
LENOVO-GbTOR-G8264-MIB
OID
.1.3.6.1.4.1.26543.2.7.6.1.3.1.15
Type
scalar
Access
readonly
Status
current
Parent
hardware
Siblings
7

Syntax

Enumeration

Values & Constraints

Enumerated Values
1ok
2noncritical
3critical