storageDeviceTemperature
LEFTHAND-NETWORKS-NSM-STORAGE-MIB ·
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.9
Object
The device temperature.
Context
- MIB
- LEFTHAND-NETWORKS-NSM-STORAGE-MIB
- OID
.1.3.6.1.4.1.9804.3.1.1.2.4.2.1.9- Type
- column
- Access
- readonly
- Status
- current
- Units
- Celsius
- Parent
- storageDeviceEntry
- Table
- storageDeviceTable
- Siblings
- 21
Syntax
Celsius SNMPv2-SMIGauge32
- Source
- SNMPv2-SMIGauge32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| storageDeviceIndex The index for the storageDeviceTable table. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.1 |
| storageDeviceTemperatureCritical The value where the temperature becomes critical. | column | Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.10 |
| storageDeviceTemperatureLimit The maximum temperature that can be tolerated. | column | Celsius SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.11 |
| storageDeviceTemperatureStatus The device temperature status. | column | Enumeration | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.12 |
| storageDeviceLabel The the device bay/slot label. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.13 |
| storageDeviceName The device name. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.14 |
| storageDeviceRaidDevice The RAID device LUN for the storage device. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.15 |
| storageDeviceFirmwareVersion The device firmware version. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.16 |
| storageDeviceSmartHealth The device SMART health status. Possible values are: normal, marginal, faulty | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.17 |
| storageDeviceSmartHealthStatus The device SMART health status. | column | Enumeration | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.18 |
| storageDeviceCapacity The capacity of the device. | column | MB SNMPv2-SMIInteger32 | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.19 |
| storageDeviceModel The device model. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.2 |
| storageDeviceHotRemovable The hot removable status of the device. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.20 |
| storageDeviceClass The device class describes the interface type and speed. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.3 |
| storageDeviceCapacityInBytes obsolete The capacity of the device. Obsolete in SAN/iQ 8.5. Use 'storageDeviceCapacity'. | column | Blocks (512 bytes) HCNUM-TCCounterBasedGauge64 | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.4 |
| storageDeviceMode The device mode. Possible modes are: active, inactive, hot spare, rebuilding, uninitialized, foreign | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.5 |
| storageDeviceChain obsolete The storage device chain. Obsolete in SAN/iQ 8.5. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.6 |
| storageDeviceSerialNumber The device serial number. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.7 |
| storageDeviceState The device (presence) state. Possible values are: on_and_secured, off_and_secured, off_or_removed | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.90 |
| storageDeviceStatus The device status. | column | Enumeration | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.91 |
| storageDeviceRowStatus obsolete The table row status. Obsolete in SAN/iQ 8.5. | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.9804.3.1.1.2.4.2.1.99 |