gs2310pplusPoeAutoCheckIntervalTime

LANCOM-GS2310PPLUS-MIB · .1.3.6.1.4.1.2356.800.3.2312.2.13.3.2.1.3

Object

column r/w Integer32
Device will send checking message to PD each interval time.
default: 30,
range: 10-120 sec.

Context

MIB
LANCOM-GS2310PPLUS-MIB
OID
.1.3.6.1.4.1.2356.800.3.2312.2.13.3.2.1.3
Type
column
Access
readwrite
Status
current
Parent
gs2310pplusPoeAutoCheckEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'LANCOM-GS2310PPLUS-MIB' -M '/opt/observium/mibs/lancom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LANCOM-GS2310PPLUS-MIB::gs2310pplusPoeAutoCheckIntervalTime'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'LANCOM-GS2310PPLUS-MIB' -M '/opt/observium/mibs/lancom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'LANCOM-GS2310PPLUS-MIB::gs2310pplusPoeAutoCheckIntervalTime.<gs2310pplusPoeAutoCheckPort>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'LANCOM-GS2310PPLUS-MIB' -M '/opt/observium/mibs/lancom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'LANCOM-GS2310PPLUS-MIB::gs2310pplusPoeAutoCheckIntervalTime'

Syntax

Integer32

Values & Constraints

Object Constraints
range: 10-120