gs2328pMLDSnoopingVLANCompatibility
LANCOM-GS-2328P-MIB ·
.1.3.6.1.4.1.2356.800.3.2331.2.17.2.1.4
Object
column
r/w
Enumeration
Compatibility is maintained by hosts and routers taking appropriate actions depending on the versions of IGMP operating on hosts and routers within a network. The allowed selection is MLD-Auto, Forced MLDv1, Forced MLDv2, default compatibility value is IGMP-Auto.
Context
- MIB
- LANCOM-GS-2328P-MIB
- OID
.1.3.6.1.4.1.2356.800.3.2331.2.17.2.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- gs2328pMLDSnoopingVLANEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
0 | mldAuto |
1 | forcedMLDv1 |
2 | forcedMLDv2 |
3 | none |