dryOutputConfig
Jetnet5310G ·
.1.3.6.1.4.1.24062.2.3.9.11.1.1.1.3
Object
column
r/w
Enumeration
The dry output mechanism of fault relay will be enabled or disabled.
Context
- MIB
- Jetnet5310G
- OID
.1.3.6.1.4.1.24062.2.3.9.11.1.1.1.3- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- faultRelayEntry
- Table
- faultRelayTable
- Siblings
- 13
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| faultRelayId Index of fault relay. | column | Enumeration | .1.3.6.1.4.1.24062.2.3.9.11.1.1.1.1 |
| pingResetConfig The ping reset mechanism of fault relay will be enabled or disable. | column | Enumeration | .1.3.6.1.4.1.24062.2.3.9.11.1.1.1.10 |
| pingResetIP The fault relay will be trigger if fail to ping the assigned
IP address. | column | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.24062.2.3.9.11.1.1.1.11 |
| pingResetTime Reset the ping process after pingResetTime, and then wait
pingHoldTime to ping again. | column | Integer32 | .1.3.6.1.4.1.24062.2.3.9.11.1.1.1.12 |
| pingResetHoldTime Reset the ping process after pingResetTime, and then wait
pingHoldTime to ping again. | column | Integer32 | .1.3.6.1.4.1.24062.2.3.9.11.1.1.1.13 |
| ringFailureConfig The fault relay will be triggered if the configured
ring fails. | column | Enumeration | .1.3.6.1.4.1.24062.2.3.9.11.1.1.1.14 |
| diConfig The fault relay will be triggered if digital input is low
or high. | column | Enumeration | .1.3.6.1.4.1.24062.2.3.9.11.1.1.1.2 |
| dryOutputOnPeriod The fault relay will be closed after a period (in seconds).
Together with dryOutputOffPeriod, the fault relay can
be configured to continue on and off. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.24062.2.3.9.11.1.1.1.4 |
| dryOutputOffPeriod The fault relay will be opened after a period (in seconds).
Together with dryOutputOnPeriod, the fault relay can
be configured to continue on and off. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.24062.2.3.9.11.1.1.1.5 |
| powerFailureConfig The fault relay will be triggered if the configured
power fails. Any means either power 1 or power2 fails | column | Enumeration | .1.3.6.1.4.1.24062.2.3.9.11.1.1.1.6 |
| linkFailureConfig The fault relay will be trigger if any of the configured
links fails. | column | Q-BRIDGE-MIBPortList | .1.3.6.1.4.1.24062.2.3.9.11.1.1.1.7 |
| pingConfig The ping failure mechanism of fault relay will be enabled or disable. | column | Enumeration | .1.3.6.1.4.1.24062.2.3.9.11.1.1.1.8 |
| pingIP The fault relay will be trigger if fail to ping the assigned
IP address. | column | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.24062.2.3.9.11.1.1.1.9 |