jnxSoamLmCfgMeasurementInterval
JUNIPER-SOAM-PM-MIB ·
.1.3.6.1.4.1.2636.3.78.1.2.1.1.25
Object
column
minutes Unsigned32
This object specifies the Measurement Interval for FLR statistics,
in minutes. A Measurement Interval of 15 minutes needs to be supported,
other intervals may be supported.
This object can only be written at row creation time and cannot be
modified once it has been created.
Context
- MIB
- JUNIPER-SOAM-PM-MIB
- OID
.1.3.6.1.4.1.2636.3.78.1.2.1.1.25- Type
- column
- Access
- readonly
- Status
- current
- Units
- minutes
- Parent
- jnxSoamLmCfgEntry
Syntax
minutes Unsigned32
Values & Constraints
Object Constraints
range: 1-525600