jnxSoamDmCfgNumIntervalsStored
JUNIPER-SOAM-PM-MIB ·
.1.3.6.1.4.1.2636.3.78.1.3.1.1.12
Object
column
Unsigned32
This object specifies the number of completed Measurement Intervals
to store in the history statistic table.
At least 32 completed Measurement Intervals are to be stored. 96
Measurement Intervals are recommended to be stored.
This object can only be written at row creation time and cannot be
modified once it has been created.
Context
- MIB
- JUNIPER-SOAM-PM-MIB
- OID
.1.3.6.1.4.1.2636.3.78.1.3.1.1.12- Type
- column
- Access
- readonly
- Status
- current
- Parent
- jnxSoamDmCfgEntry
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-1000