jnxPingCtlEgressJitterThreshold
JUNIPER-PING-MIB ·
.1.3.6.1.4.1.2636.3.7.1.2.1.12
Object
column
r/w
microseconds Unsigned32
The maximum allowed jitter in the egress trip time over the course of any test. Jitter is defined as the difference between the maximum and minimum egress trip times measured over the course of a single test (jnxPingResultsMaxSrcDstt minus jnxPingResultsMinSrcDstt). If the measured jitter exceeds this threshold, a jnxPingEgressJitterThresholdExceeded trap will be sent. This applies only if the probe type (pingCtlType) provides one way delay measurements. Currently jnxPingIcmpTimeStamp is the only supported probe type with this property.
Context
- MIB
- JUNIPER-PING-MIB
- OID
.1.3.6.1.4.1.2636.3.7.1.2.1.12- Type
- column
- Access
- readwrite
- Status
- current
- Units
- microseconds
- Parent
- jnxPingCtlEntry
Syntax
microseconds Unsigned32
Values & Constraints
Object Constraints
range: 0-60000000