boardSpeedFaultPort

IRM3-MIB · .1.3.6.1.4.1.52.1.2.2.3.3.8

Object

scalar mandatory Integer32
This object indicates which ring speed detect circuit(s) caused the
fault, if there was one.  The return code indicates the location on
the board feeding the speed detect circuit(s).  Ring in means the
circuit on the back-up path between the ring out port and the ring
in port.  FNB means the circuit between the ring in port and the FNB.
NotApplicable means that a ring Speed Fault has not occurred.
Since more than one circuit can cause the fault, the return code is
the sum of the following values:
               1 - FNB
               2 - RingIn
               4 - RingOut
               8 - NotApplicable

Context

MIB
IRM3-MIB
OID
.1.3.6.1.4.1.52.1.2.2.3.3.8
Type
scalar
Access
readonly
Status
mandatory
Parent
tokenRingB

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'IRM3-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IRM3-MIB::boardSpeedFaultPort.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'IRM3-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'IRM3-MIB::boardSpeedFaultPort'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647