eqptFruInsertionDate
INFINERA-ENTITY-EQPT-MIB ·
.1.3.6.1.4.1.21296.2.2.1.9.1.1.1.28
Object
column
SNMPv2-TCDisplayString
No description available.
Context
- MIB
- INFINERA-ENTITY-EQPT-MIB
- OID
.1.3.6.1.4.1.21296.2.2.1.9.1.1.1.28- Type
- column
- Access
- readonly
- Status
- current
- Parent
- eqptEntry
- Table
- eqptTable
- Siblings
- 28
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eqptMoId MO identifier for this object | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.1 |
| eqptInstalledEqptType The equipment type installed in the slot. | column | INFINERA-TC-MIBInfnEqptType | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.10 |
| eqptBaseCircuitPackType Base Circuit Pack Type. | column | INFINERA-TC-MIBInfnCircuitPackType | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.11 |
| eqptCLEI The Common Language Equipment Identifier of the equipment. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.12 |
| eqptSAFpgaUpgradePending Service affecting Fpga upgrade pending indication. | column | Enumeration | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.13 |
| eqptSAFpgaUpgradeFlag Service affecting Fpga upgrade control. | column | Enumeration | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.14 |
| eqptEqptMaxPowerDraw Parameter denoting the estimated power drawn by the FRU. This varies
depending on the type of the FRU. | column | INFINERA-TC-MIBFloatHundredths | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.15 |
| eqptLastRebootTime The last time this equipment booted, expressed in the format
YYYY-MM-DD<Space>hh:mm:ss. This value will be a zero-length string if
the boot time is unknown or not applicable. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.16 |
| eqptLastRebootReason The reason which caused the last circuit pack reboot. | column | INFINERA-TC-MIBInfnLastRebootReason | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.17 |
| eqptInletTemp The inlet temperature in degree Celsius. | column | degrees Celcius INFINERA-TC-MIBFloatArbitraryPrecision | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.18 |
| eqptOutletTemp The outlet temperature in degree Celsius. | column | degrees Celcius INFINERA-TC-MIBFloatArbitraryPrecision | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.19 |
| eqptLabel An identifier to identify the managed object. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.2 |
| eqptPartNumber | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.20 |
| eqptSerialNumber | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.21 |
| eqptManufacturedDate | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.22 |
| eqptVendorId | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.23 |
| eqptHardwareVersion | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.24 |
| eqptFirmwareVersion | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.25 |
| eqptPON | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.26 |
| eqptUniversalSlotUsage | column | Integer32 | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.27 |
| eqptRedundancyStatus Describes the redundancy state on controller card | column | INFINERA-TC-MIBInfnCorrelatedRedunStatus | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.29 |
| eqptAdministrativeState Parameter that enables to allow or prohibit the managed object from providing its designated service. | column | INFINERA-TC-MIBInfnAdminState | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.3 |
| eqptOperationalState It describes the actual state of the managed object in terms of its
ability to provide service. | column | INFINERA-TC-MIBInfnOperationalState | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.4 |
| eqptAvailabilityState It describes the actual state of the managed object in terms of its
ability to provide service. | column | INFINERA-TC-MIBInfnAvailabilityState | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.5 |
| eqptAlarmReportControl Enable or disable the alarm reporting by the managed object. | column | INFINERA-TC-MIBInfnArc | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.6 |
| eqptOpStateQualifierList It describes the secondry state of the managed object. | column | INFINERA-TC-MIBInfnOpsQualifierList | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.7 |
| eqptAlarmInhibitState Indicates the alarm reporting status of the managed object. | column | INFINERA-TC-MIBInfnArc | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.8 |
| eqptProvEqptType The configured equipment type. | column | INFINERA-TC-MIBInfnEqptType | .1.3.6.1.4.1.21296.2.2.1.9.1.1.1.9 |