ieee8021SpbmSysMode

IEEE8021-SPB-MIB · .1.3.111.2.802.1.1.26.1.1.8

Object

scalar r/w IEEE8021SpbMode
Indication of supporting SPBM mode
auto(=1)/manual(=2)
auto => enable SPBM mode and auto allocate SPsourceID.
manual => enable SPBM mode and manually assign SPsourceID.
This object is persistent.

Context

MIB
IEEE8021-SPB-MIB
OID
.1.3.111.2.802.1.1.26.1.1.8
Type
scalar
Access
readwrite
Status
current
Parent
ieee8021SpbSys
Groups
2

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'IEEE8021-SPB-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IEEE8021-SPB-MIB::ieee8021SpbmSysMode.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'IEEE8021-SPB-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'IEEE8021-SPB-MIB::ieee8021SpbmSysMode'

Syntax

Source
IEEE8021SpbMode
Base type
Enumeration

Values & Constraints

Type Values
1auto
2manual