ieee8021FqtssAdminIdleSlopeMs
IEEE8021-FQTSS-MIB ·
.1.3.111.2.802.1.1.16.1.1.1.1.5
Object
column
r/w
bits per second Unsigned32
The most significant 32 bits of the bandwidth,
in bits per second, that the manager desires to allocate
to the traffic class as idleSlope(N). This object MUST be
read or written at the same time as
ieee8021FqtssAdminIdleSlopeLs,
which represents the LS 32 bits of the value, in order
for the read or write operation to succeed.
If SRP is supported and in operation, then the reserved
bandwidth is determined by the operation of SRP, and any
changes to the value of this object have no effect on the
operational value of idleSlope(N).
The value of this object MUST be retained across
reinitializations of the management system.
Context
- MIB
- IEEE8021-FQTSS-MIB
- OID
.1.3.111.2.802.1.1.16.1.1.1.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Units
- bits per second
- Parent
- ieee8021FqtssBapEntry
Syntax
bits per second Unsigned32
Values & Constraints
No enumerated values or constraints recorded.