ieee8021BridgePortUseDEI

IEEE8021-BRIDGE-MIB · .1.3.111.2.802.1.1.2.1.3.1.1.4

Object

column r/w SNMPv2-TCTruthValue
If the Use_DEI is set to true(1) for the Port then the 
drop_eligible parameter is encoded in the DEI of transmitted
frames, and the drop_eligible parameter shall be true(1) for a
received frame if the DEI is set in the VLAN tag or the Priority
Code Point Decoding Table indicates drop_eligible True for
the received PCP value. If the Use_DEI parameter is false(2),
the DEI shall be transmitted as zero and ignored on receipt.
The default value of the Use_DEI parameter is false(2).

Context

MIB
IEEE8021-BRIDGE-MIB
OID
.1.3.111.2.802.1.1.2.1.3.1.1.4
Type
column
Access
readwrite
Status
current
Parent
ieee8021BridgePortPriorityEntry
Table
ieee8021BridgePortPriorityTable
Siblings
5

Syntax

SNMPv2-TCTruthValue
Source
SNMPv2-TCTruthValue
Base type
Enumeration

Values & Constraints

Type Values
1true
2false

Related Objects

Sibling Objects