hwGlobalHealthStatus
IBM-GbTOR-G8264CS-MIB ·
.1.3.6.1.4.1.20301.2.7.15.1.3.1.15
Object
scalar
Enumeration
This variable summarizes the statuses of several key elements of the device. OK: - All temperature sensors are below the warning threshold (eg. < 85 C); - All fans are running at >= 100 RPMs; - Both power supplies are on; - No panic dump exists in flash. Non-critical: - One or more temperature sensors is in the warning range (eg. >= 85 and < 100 C); - A panic dump exists in flash. Critical: - One or more temperature sensors is in the failure range (eg. >= 100 C); - One or more fans are running < 100 RPM; - One power supply is off.
Context
- MIB
- IBM-GbTOR-G8264CS-MIB
- OID
.1.3.6.1.4.1.20301.2.7.15.1.3.1.15- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- hardware
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.