switchRenumberUnitID

Hirschmann-GIGA-LION-24TP-MIB · .1.3.6.1.4.1.248.13.7.5.1.1.14

Object

scalar r/w Enumeration
The value renumber will automatically assign an ID to
units in the stack; all UNIT IDs will be contiguous.
The system configurations are not changed but the system
will restart after renumbering is completed.

Context

MIB
Hirschmann-GIGA-LION-24TP-MIB
OID
.1.3.6.1.4.1.248.13.7.5.1.1.14
Type
scalar
Access
readwrite
Status
current
Parent
switchMgt

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'Hirschmann-GIGA-LION-24TP-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'Hirschmann-GIGA-LION-24TP-MIB::switchRenumberUnitID.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'Hirschmann-GIGA-LION-24TP-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'Hirschmann-GIGA-LION-24TP-MIB::switchRenumberUnitID'

Syntax

Enumeration

Values & Constraints

Enumerated Values
1renumber
2noRenumber