hwSctpParaRtoMax
HWMUSA-SIGTRAN-MIB ·
.1.3.6.1.4.1.2011.2.6.7.6.1.9.2
Object
scalar r/w
Integer32
The maximum RTO. For Mg interface, default value 3000. For Iua-Link, default value 60000. To the UA5000R15C05, the value range is (200..120000). To other products, the value range is (3000..90000). Unit: millisecond
Context
- MIB
- HWMUSA-SIGTRAN-MIB
- OID
.1.3.6.1.4.1.2011.2.6.7.6.1.9.2- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- hwSctpParaTable
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HWMUSA-SIGTRAN-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HWMUSA-SIGTRAN-MIB::hwSctpParaRtoMax.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HWMUSA-SIGTRAN-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HWMUSA-SIGTRAN-MIB::hwSctpParaRtoMax'
Syntax
Integer32
Values & Constraints
Object Constraints
range: 200-120000