hwMifSctpCfgParaHbInterval
HWMUSA-SIGTRAN-MIB ·
.1.3.6.1.4.1.2011.2.6.7.6.1.14.1.17
Object
column
r/w
Integer32
Heartbeat interval. For Mg interface, 10000~120000 is valid. For Iua-Link, 2000~120000 is valid. Default: 10000(Mg interface),30000(Iua-Link) Unit: millisecond
Context
- MIB
- HWMUSA-SIGTRAN-MIB
- OID
.1.3.6.1.4.1.2011.2.6.7.6.1.14.1.17- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwMifSctpCfgParaEntry
Syntax
Integer32
Values & Constraints
Object Constraints
range: 2000-120000