hwXponDeviceOntOpticalAlarmAutoMonitorSwitch

HUAWEI-XPON-COMMON-MIB · .1.3.6.1.4.1.2011.6.145.1.1.4.24

Object

scalar r/w Enumeration
The object is used to configure automatic monitoring on ONT optical alarm, the function will be disabled when the ONT is bound to optical alarm profile.
Options:
1. disable(2)      - The function is disabled
2. opticalThreshold (11)    - The function is enabled, the optical threshold is read from the optical module, which is defined by the manufacturer
3. standardThreshold(12)    - The function is enabled, the alarm threshold is defined by the standard threshold
4. invalid(-1)       - Indicates that the query fails or no information is detected
The default value is disable(2).

Context

MIB
HUAWEI-XPON-COMMON-MIB
OID
.1.3.6.1.4.1.2011.6.145.1.1.4.24
Type
scalar
Access
readwrite
Status
current
Parent
hwXponDeviceCommonGlobalObjects

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HUAWEI-XPON-COMMON-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-XPON-COMMON-MIB::hwXponDeviceOntOpticalAlarmAutoMonitorSwitch.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HUAWEI-XPON-COMMON-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HUAWEI-XPON-COMMON-MIB::hwXponDeviceOntOpticalAlarmAutoMonitorSwitch'

Syntax

Enumeration

Values & Constraints

Enumerated Values
-1invalid
2disable
11opticalThreshold
12standardThreshold