hwDevSubBoardTemperatureTooHighRecoverTrap
HUAWEI-DEVICE-MIB ·
.1.3.6.1.4.1.2011.6.3.8.3.4.0.5
Object
notification
This trap message is reported when the current temperature of service sub board recovers to the normal range from high temperature.
Context
- MIB
- HUAWEI-DEVICE-MIB
- OID
.1.3.6.1.4.1.2011.6.3.8.3.4.0.5- Type
- notification
- Status
- current
- Parent
- hwDevSubBoardTrapsPrefix
- Siblings
- 8
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwDevSubBoardTypeInconsistentTrap This trap message is reported when the configured daughter board type
or quantity is not the same as the actual type or quantity. | notification | - | .1.3.6.1.4.1.2011.6.3.8.3.4.0.1 |
| hwDevSubBoardMisMatchTrap This trap message is reported when the combination of daughter board type
in main control board is not supported. | notification | - | .1.3.6.1.4.1.2011.6.3.8.3.4.0.2 |
| hwDevSubBoardReplacedTrap This trap message is reported when the board is successfully
replaced by another board of the same type. | notification | - | .1.3.6.1.4.1.2011.6.3.8.3.4.0.3 |
| hwDevSubBoardTemperatureTooHighTrap This trap message is reported when the current temperature of service sub board
exceed the high temperature threshold. | notification | - | .1.3.6.1.4.1.2011.6.3.8.3.4.0.4 |
| hwDevSubBoardFaultTrap This trap message is reported when the communication of the board interrupted. | notification | - | .1.3.6.1.4.1.2011.6.3.8.3.4.0.6 |
| hwDevSubBoardFaultRecoverTrap This trap message is reported when the communication of the board restored. | notification | - | .1.3.6.1.4.1.2011.6.3.8.3.4.0.7 |
| hwDevSubBoardActStdInconsistentTrap This trap message is reported when the subboards on the active and standby control boards are inconsistent. | notification | - | .1.3.6.1.4.1.2011.6.3.8.3.4.0.8 |
| hwDevSubBoardActStdInconsistentRestoreTrap This trap message is reported when the subboards on the active and standby control boards recover consistent. | notification | - | .1.3.6.1.4.1.2011.6.3.8.3.4.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwFrameIndex The index of a shelf in the device. | column | Integer32 | .1.3.6.1.4.1.2011.6.3.3.1.1.1 |
| hwSlotIndex A slot index is used to identify the location of a board in a shelf.
You can locate a board in a shelf according to hwFrameIndex and hwSlotIndex.
For the hwFrameIndex object, refe… | column | Integer32 | .1.3.6.1.4.1.2011.6.3.3.2.1.1 |
| hwSubboardID The index ID of sub board. | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.3.8.1.48 |
| hwSlotTemperature The temperature of the board. (Unit:centigrade)
The value 0X7FFFFFFF indicates invalid temperature. | column | centigrade SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.3.3.2.1.13 |