hwPacketCable1DotxTimerT1
HUAWEI-CMTS-MIB ·
.1.3.6.1.4.1.2011.6.180.1.1.22.1.1.6
Object
scalar r/w
secondsUnsigned32
In PacketCable 1.x this timer is implemented in the CMTS in the Gate state machine, and limits the period of time that may elapse between the authorization and a commit is performed. In the set operation, if is set to 0, it indicates that reset the timer to the default value. In the query operation, if it is not set, the value obtained is the default value. Range: 0 | 1..1000000 Default: 200
Context
- MIB
- HUAWEI-CMTS-MIB
- OID
.1.3.6.1.4.1.2011.6.180.1.1.22.1.1.6- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- hwPacketCableConfigObject
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HUAWEI-CMTS-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-CMTS-MIB::hwPacketCable1DotxTimerT1.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HUAWEI-CMTS-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HUAWEI-CMTS-MIB::hwPacketCable1DotxTimerT1'
Syntax
secondsUnsigned32
Values & Constraints
Object Constraints
range: 0-1000000