hwDocsPnmCmtsUsFecStatisticEnable
HUAWEI-CMTS-MIB ·
.1.3.6.1.4.1.2011.6.180.1.1.20.86.1.1
Object
Setting this object to a value of 'true' instructs the CMTS to begin
collection of FEC Statistic data and when enabled, the CMTS continues
producing new data at its own rate.
This value is only allowed to be set to 'true' if the value of
'hwDocsPnmCmtsUsFecStatisticMeasStatus' is a value other than 'busy'.
Setting this object to a value of 'false' instructs the CM to stop
the collection of FEC Statistic data.
This object returns 'true' if the CMTS is actively collecting FEC Statistic
data. Otherwise it returns 'false'.
Interaction with other table rows:
- This object returns 'inconsistentValue' if set to 'true' while the
value of 'hwDocsPnmCmtsUsFecStatisticMeasStatus' is a value of 'busy'.
- Default values are provided for read-write objects in this table; thus,
this object may be set to 'true' without explicitly setting these values.
However, the default values may not be appropriate and care should be
taken to insure these values are correct for the desired test case.
- Setting this value to 'true' will change the value of the
'hwDocsPnmCmtsUsFecStatisticMeasStatus' to 'busy'.
Context
- MIB
- HUAWEI-CMTS-MIB
- OID
.1.3.6.1.4.1.2011.6.180.1.1.20.86.1.1- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwDocsPnmCmtsUsFecStatisticEntry
Syntax
SNMPv2-TCTruthValue
Values & Constraints
No enumerated values or constraints recorded.