hwCmtsUsSpectrumMonitorFrequencyEnd
HUAWEI-CMTS-MIB ·
.1.3.6.1.4.1.2011.6.180.1.1.20.56.1.6
Object
column r/w
HzInteger32
Indicates the end frequency for upstream spectrum scanning. Requirement: The difference between the end frequency and the start frequency must be greater than the upstream frequency spectrum scanning resolution. -1 represent that the upstream spectrum configuration of end frequency has invalid configuration data. Default: 102000000
Context
- MIB
- HUAWEI-CMTS-MIB
- OID
.1.3.6.1.4.1.2011.6.180.1.1.20.56.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Units
- Hz
- Parent
- hwCmtsUsSpectrumMonitorCfgEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HUAWEI-CMTS-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-CMTS-MIB::hwCmtsUsSpectrumMonitorFrequencyEnd'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HUAWEI-CMTS-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-CMTS-MIB::hwCmtsUsSpectrumMonitorFrequencyEnd.<ifIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HUAWEI-CMTS-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HUAWEI-CMTS-MIB::hwCmtsUsSpectrumMonitorFrequencyEnd'
Syntax
HzInteger32
Values & Constraints
Object Constraints
range: -1-204000000