hwCmtsUsSpectrumMonitorFrequencyEnd

HUAWEI-CMTS-MIB · .1.3.6.1.4.1.2011.6.180.1.1.20.56.1.6

Object

column r/w HzInteger32
Indicates the end frequency for upstream spectrum scanning.
Requirement: The difference between the end frequency and the start frequency must be greater than the upstream frequency spectrum scanning resolution.
-1 represent that the upstream spectrum configuration of end frequency has invalid configuration data.
Default: 102000000

Context

MIB
HUAWEI-CMTS-MIB
OID
.1.3.6.1.4.1.2011.6.180.1.1.20.56.1.6
Type
column
Access
readwrite
Status
current
Units
Hz
Parent
hwCmtsUsSpectrumMonitorCfgEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HUAWEI-CMTS-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-CMTS-MIB::hwCmtsUsSpectrumMonitorFrequencyEnd'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HUAWEI-CMTS-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-CMTS-MIB::hwCmtsUsSpectrumMonitorFrequencyEnd.<ifIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HUAWEI-CMTS-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HUAWEI-CMTS-MIB::hwCmtsUsSpectrumMonitorFrequencyEnd'

Syntax

HzInteger32

Values & Constraints

Object Constraints
range: -1-204000000