hwCmtsRfPowerDsMonitorFreqFunction

HUAWEI-CMTS-MIB · .1.3.6.1.4.1.2011.6.180.1.1.20.74.1.6

Object

column r/w Enumeration
Indicates the monitoring frequency function of the RF output port.
Not more than one monitoring frequency with the adjust-power function and of CATV type (CATV types include catv-qam and catv-cw) can be configured.
Not more than one monitoring frequency with the adjust-power function and of DOCSIS type (DOCSIS type includes doc-scqam) can be configured.
Default: adjustPower(1)
Options:
1. adjustPower(1) -adjusts the power     
2. queryPower(2)  -only queries the power

Context

MIB
HUAWEI-CMTS-MIB
OID
.1.3.6.1.4.1.2011.6.180.1.1.20.74.1.6
Type
column
Access
readwrite
Status
current
Parent
hwCmtsRfPowerDsMonitorConfigEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HUAWEI-CMTS-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-CMTS-MIB::hwCmtsRfPowerDsMonitorFreqFunction'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HUAWEI-CMTS-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HUAWEI-CMTS-MIB::hwCmtsRfPowerDsMonitorFreqFunction.<hwFrameIndex>.<hwCmtsRfPowerDsMonitorIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HUAWEI-CMTS-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HUAWEI-CMTS-MIB::hwCmtsRfPowerDsMonitorFreqFunction'

Syntax

Enumeration

Values & Constraints

Enumerated Values
1adjustPower