hpnicfprialarmRisingThreshold

HPN-ICF-RMON-EXT-MIB · .1.3.6.1.4.1.11.2.14.11.15.8.4.4.1.1.8

Object

column r/w Integer32
A threshold for the sampled statistic.  When the current
sampled value is greater than or equal to this threshold,
and the value at the last sampling interval was less than
this threshold, a single event will be generated.
A single event will also be generated if the first
sample after this entry becomes valid is greater than or
equal to this threshold and the associated
alarmStartupAlarm is equal to risingAlarm(1) or
risingOrFallingAlarm(3).
              
After a rising event is generated, another such event
will not be generated until the sampled value
falls below this threshold and reaches the
alarmFallingThreshold.
              
This object may not be modified if the associated
alarmStatus object is equal to valid(1).

Context

MIB
HPN-ICF-RMON-EXT-MIB
OID
.1.3.6.1.4.1.11.2.14.11.15.8.4.4.1.1.8
Type
column
Access
readwrite
Status
current
Parent
hpnicfprialarmEntry
Table
hpnicfprialarmTable
Siblings
14

Syntax

Integer32
Source
COPS-PR-SPPIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647

Related Objects

Sibling Objects