scanner-lamp-gain-value

HP-LASERJET-COMMON-MIB · .1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.2.8

Object

scalar mandatory SNMPv2-TCDisplayString
Provides PWM and analog gain for the color channels. The range
will vary based on scan mode. The device specific POS should
describe the valid range. The format is the following:   
    PWM value; red analog gain; green analog gain; blue analog
	gain.   
Additional information:
The range will vary based on scan mode.  The values
will differ from those of San Diego.  The initial value
can be obtained at the start of warmup and the final
value can be obtained at the end of warmup. The warmup period is about
2 minutes.  The format is the following PWM value; red analog gain;
green analog gain; blue analog gain;.  The valid values for PWM value
are 580 - 730 and the valid values for analog gains are 1.00-5.80.
The gains are reported with accuracy to 2 decimal places.
A sample return value would be '584;1.00;1.34;1.00;'

Context

MIB
HP-LASERJET-COMMON-MIB
OID
.1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.2.8
Type
scalar
Access
readonly
Status
mandatory
Parent
status-scanner

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HP-LASERJET-COMMON-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HP-LASERJET-COMMON-MIB::scanner-lamp-gain-value.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HP-LASERJET-COMMON-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HP-LASERJET-COMMON-MIB::scanner-lamp-gain-value'

Syntax

Source
SNMPv2-TCDisplayString
Base type
OctetString
Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
          
character set, as defined in pages 4, 10-11 of RFC 854.
          
To summarize RFC 854, the NVT ASCII repertoire specifies:
          
  - the use of character codes 0-127 (decimal)
          
  - the graphics characters (32-126) are interpreted as
    US ASCII
          
  - NUL, LF, CR, BEL, BS, HT, VT and FF have the special
    meanings specified in RFC 854
          
  - the other 25 codes have no standard interpretation
          
  - the sequence 'CR LF' means newline
          
  - the sequence 'CR NUL' means carriage-return
          
  - an 'LF' not preceded by a 'CR' means moving to the
    same column on the next line.
          
  - the sequence 'CR x' for any x other than LF or NUL is
    illegal.  (Note that this also means that a string may
    end with either 'CR LF' or 'CR NUL', but not with CR.)
          
Any object defined using this syntax may not exceed 255
characters in length.

Values & Constraints

Type Constraints
range: 0..255