scan-calibration-download
HP-LASERJET-COMMON-MIB ·
.1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.2.5
Object
scalar
mandatory
r/w
OctetString
Returns or changes the state of the calibration operation. cScanCalibrationIdle - indicates that calibration is not in progress. cScanCalibrationStart - This state is set by host to request calibration initiation. Device should not set to this state. cScanCalibrationActive - Indicates device is in calibration mode. Device sets cScanCalibrationActive to signal calibration is in process. cScanCalibrationAborted - Set by device to indicate calibration was prematurely terminated. Set by host when a calibration error occurs. cScanCalibrationSendDataRequest - Set by host when host wants to send data to the device. cScanCalibrationSendDataRequestOK - Set by the device to tell the host that the device is ready to accept data. cScanCalibrationSendDataRequestDone -Set by the device to indicate the data was received by the device. cScanCalibrationRequestScanBuffer - Set by the host to request a buffer from the device. cScanCalibrationDone - Set by the host to inform the device calibration is complete. The sequence of bits being set and the restrictions for setting bits should be documented in the device POS. Additional information: This object was originally defined for use on HP LaserJet 1100. HP Laserjet 3200 we will not be using values 3-6. These are no longer applicable since the calibration is completely contained within firmware.
Context
- MIB
- HP-LASERJET-COMMON-MIB
- OID
.1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.2.5- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- status-scanner
- Siblings
- 9
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| not-ready-source-scanner mandatory Indicates whether and why the scanner is not ready. A
set bit indicates a problem.
Additional information:
ISSUES: HP LaserJet 1100 only used
cScannerFeederJam. Tahiti does not… | scalar | OctetString | .1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.2.1 |
| scanner-reference-position mandatory Provides 3 pairs of x,y coordinates within a specified range of
the calibrate reference position. The device specific POS
should specify the valid ranges. The format is the follow… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.2.10 |
| scanner-sensor-manufacturer mandatory Reports the scan sensor manufacturer. The device specific POS
should list valid manufacturers.
Additional information:
Reports the scan sensor manufacturer. The device specific
P… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.2.11 |
| copy-scanner-dimensions mandatory This object is used to obtain the exact pixel scan dimensions
for copy. The dimensions returned correspond to the quality,
reduce/enlarge, and media size currently selected.
Addit… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.2.13 |
| scan-resolution-range mandatory Enumerates the range of selectable scanning resolutions.
Format as follows: Each supported resolution is in the
format: (m)x(n) where m describes the x dpi resolution
along the pa… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.2.3 |
| scan-calibration-error mandatory Error status of the most recent calibration session.
eNoError(1) - The calibation was successful.
eUnknownCalibrationError(2) - An unknown error
occurred.
eScannerFeederEmpt… | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.2.6 |
| scanner-button-status mandatory Indicates the scanner button has been pressed. The value
changes to eOn(2) when the button is pressed. The host
acknowledges the button press by setting the value to
eOff(1). | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.2.7 |
| scanner-lamp-gain-value mandatory Provides PWM and analog gain for the color channels. The range
will vary based on scan mode. The device specific POS should
describe the valid range. The format is the following: … | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.2.8 |
| scanner-light-monitor-window mandatory Provides the pixel at which the LMW starts, as the ratio of the
average LMW value to the six pixel average value. The device
specific pos should specify the valid ranges for each … | scalar | OctetString | .1.3.6.1.4.1.11.2.3.9.4.2.1.2.2.2.9 |