run-location

HP-LASERJET-COMMON-MIB · .1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.21

Object

scalar mandatory r/w Integer32
Returns or changes the location from which code
executes. The object allows the user to pick a memory
bank to run code from which is different than the
default running code bank. A value of 0 means the code
executes from the default code bank, which should be
documented in the device POS. The list of supported
values should be documented in the device POS. Setting
to an unsupported value causes the device to return
<badValue>.
Additional information:
Returns or changes the location from which code
		should be run.  The object allows the user to pick a ram bank
		to run code from which is potentially faster than the onboard
		ROM.  LaserJet 8100 Series and LaserJet 8000 Series support values of 0,4-9.  A value of 0
		means run code from default ROM device.  Values other than 0
		indicate a valid RAM bank of size >= 8MBs.  Setting to an
		unsupported value causes the printer to leave the run location
		set to its previous value.

Context

MIB
HP-LASERJET-COMMON-MIB
OID
.1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.21
Type
scalar
Access
readwrite
Status
mandatory
Parent
settings-system
Siblings
25

Syntax

Integer32

Values & Constraints

Enumerated Values
1eEnglish
2eFrench
3eGerman
4eSpanish
5eItalian
6eSwedish
7eDanish
8eNorwegian
9eDutch
10eFinnish
12ePortuguese
13ePolish
14eTurkish
16eTradChinese
17eSimpChinese
18eRussian
19eCzech
20eHungarian
21eKorean
22eThai
44eUnknownLanguage

Related Objects