prtoutputremainingcapacity

HP-LASERJET-COMMON-MIB · .1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.5

Object

scalar mandatory Integer32
The remaining capacity of the possible output sub-unit
capacity in output sub-unit capacity units (PrtCapacityUnitTC)
of this output sub-unit. If this output sub-unit can
reliably sense this value, the value is sensed by the
printer and may not be modified by management requests;
otherwise, the value may be written (by
a Remote Control Panel or a Management
Application).  The value (-1) means other and
specifically indicates that the sub-unit places no
restrictions on this parameter.  The value (-2) means
unknown.  The value (-3) means that the printer knows that
there remains capacity for at least one unit.
	Refer to Standard Printer MIB for more details.
        Additional information:
        Replaces PML NOT-READY-OUTBIN-FULL and
        STATUS-OUTBIN-FULL.  
        LaserJet 4000 Series is capable of determining when the face-down
        bin goes full, but not the level of that bin. LaserJet 4000 Series
        is not capable of determining whether the face-up bin
        is full. RemainingCapacity capabilities of the
        stapler/stacker, as well as unplanned HCO devices,
        are currently T.B.D.  
        LaserJet 4000 Series will report a value of 0 when the face-down
        bin is full and -3 when the face down bin is not full.

Context

MIB
HP-LASERJET-COMMON-MIB
OID
.1.3.6.1.4.1.11.2.3.9.4.2.2.9.2.1.5
Type
scalar
Access
readonly
Status
mandatory
Parent
prtOutputEntry
Siblings
22

Syntax

Integer32
Source
COPS-PR-SPPIInteger32
Base type
Integer32

Values & Constraints

Enumerated Values
1ePother
3ePon
4ePoff
5ePnotPresent
Type Constraints
range: -2147483648..2147483647

Related Objects

Sibling Objects