prtmarkersupplieslevel

HP-LASERJET-COMMON-MIB · .1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.9

Object

scalar mandatory Integer32
The current level if this supply is a container; the
remaining space if this supply is a receptacle. If this
supply container/receptacle can reliably sense this
value, the value is reported by the printer and is
read-only; otherwise, the value may be written (by a
Remote Control Panel or a Management Application). The
value (-1) means other and specifically indicates that
the sub-unit places no restrictions on this parameter.
The value (-2) means unknown.  A value of (-3) means that the
printer knows that there is some supply/remaining space,
respectively.
	Refer to Standard Printer MIB for more details.
        Additional information:
        LaserJet 4050 Series will have a new toner-measuring feature that 
        utilizes the GRIN ASIC's ability to detect the amount of pixels 
        that have been placed on a single page.  This Pixel-Counting 
        Gas Gauge should be able to calculate toner levels within 10%.  
        Because textual printing and graphics printing utilize different 
        pixel usage, accuracy for the counting algorithms have been 
        biased toward textual printing. Heavy graphics printing will 
        cause the cartridge to appear to be emptier than it really is.  
        Over time however, statistical averaging values that are kept in 
        NVRAM will help make the gauge more accurate according to 
        individual customer usage models.  The new values will vary 
        between 0 and 4600 depending on how much toner has been 
        calculated to have been used.

Context

MIB
HP-LASERJET-COMMON-MIB
OID
.1.3.6.1.4.1.11.2.3.9.4.2.2.11.1.1.9
Type
scalar
Access
readonly
Status
mandatory
Parent
prtMarkerSuppliesEntry
Siblings
7

Syntax

Integer32
Source
COPS-PR-SPPIInteger32
Base type
Integer32

Values & Constraints

Object Constraints
range: 0-63
Type Constraints
range: -2147483648..2147483647